  • DEUTSCH, seite 29
1.4.14.4 Installation and operating conditions
The motors may be used only in ambient temperatures up to 50 °C.
l
If the front flange is coated, the tolerance class N is not guaranteed.
l
Motors with flanges without wash-down coating: The flange surface must be protected by
suitable assembly against the influence by cleaning agents.
During mounting and operation protect the motor from mechanical effects which can cause
the scratches or cracks on the painted surface.The mishandling increases risk of corrosion.

1.4.14.5 Cleaning plan

Recommended cleaning plan (short form) with tested cleaning agents:
Flushing with water (40 °... 50 °C)
Flushing with low pressure. From top to bottom in the direction of the drain. Clean the drain.
Foam cleaning
Foaming from top to bottom.
Alkaline:
Acid:
Temperature:
Disinfection
Spraying with wayer (40 °... 50 °C) with low pressure. From top to bottom.
Spray disinfection:
Foam disinfection:
P3-topactive LA or P3-topax 66 (2-5%, 15 min daily)
P3-topax 56 (2%, if necessary 15 min)
cold up to 40 °C
P3-topax 91 (1-2%, if necessary 30-60 min)
P3-topactiv DES (1-3%, if necessary 10-30 min)
Kollmorgen | kdn.kollmorgen.com | June 2018