Low-temp mode
When the room temperature falls below 15°C for more than 10 minutes, the unit
will automatically enter 'Low-Temp' operation. During 'Low-Temperature'
operation, the fan will continue running with the selected fan speed. The com-
pressor will cycle on and off. The control will reset to normal operation when
the room temperature rises to 18°C or higher for 10 minutes.
Ultra-Low-temp mode
If ambient temperature is below 4°C for 4 minutes, the compressor and fan are
shut off and the four LED lights on the dehunidifier flash until the ambient
temperature is above 5°C for 8 minutes.
Defrost (De-icer) mode
When the room temperature is 15°C or lower, or the evaporator coil tempera-
ture falls below 2°C for more than 10 minutes, the unit will automatically enter
'Defrost mode'. Under these conditions, it is normal for frost and/or ice to form
on the water collection coil. In 'Defrost Mode', the compressor will be turned
off, but the fan will continue running with the selected fan speed. The compres-
sor remains off until the coil temperature rises to 9°C or higher for more than
10 minutes.
Menu Setup Mode
All the changes made by the operator will be effective immediately. Control
settings will automatically return to the last programmed settings if the setup
process is interrupted or no buttons are pressed within 2 minutes of pressing the
MENU button. You can adjust any of the settings by scrolling through the MENU.
1. Fan Speed Setup
When the dehumidifier is plugged in and started the fan speed is automatically
set to "High". You can adjust the fan to "Low" by pressing the 'MENU' button
while the unit is operating. All icons on the LCD display will be off except the
icon of the current fan speed. Pressing the 'UP' or 'DOWN' arrow button can be
used to change the fan speed. Pressing MENU again will secure the fan speed
and and will display the next setup option.
High Speed
2. Humidity Level Setup Bar
The humidity level setting bar with numbers will be displayed. The 'UP' and
'DOWN' arrows can be used to change the humidity setpoint. The desired
humidity level will be shown as solid blocks and flash on the LCD display.
Once the setting bar reaches the highest block, the control will switch to Fan-
Only Mode ( indicated by * at the top of the humidity scale), and the com-
pressor will be turned off. When the humidity level setting bar reaches below
the lowest block, the control will switch to Continuous Operation Mode and
the humidity sensor is turned off. In this mode, the dehumidifier will not be
affected by the relative humidity and operate continuously.
Humidity scale in 5 RH%
increments. Blocks indicate
percentage of relative humidity
desired. The Relative Humidity
display on the LCD indicates
actual relative humidity (RH)
Humidity Scale
3. Alarm control
Pressing the 'MENU' button again, a bell icon will be displayed on the LCD
screen. The 'UP' & 'DOWN' button can be used to enable or disable the
alarm option. The bell icon will show 'ringing lines' when the option is enabled.
Audible Alarm Off
Low Speed
level in the room.
Audible Alarm On
4. Temperature Display
By pressing the 'MENU' button again, the temperature readout will flash
with the current scale (°C or °F). Pressing the 'UP' or 'DOWN' arrow will
change the scale display.
5. Exit from Setup-Mode
Pressing the'MENU' button again will bring the control back to Operating
Mode.
Fan Motor
The fan motor contains sealed lubricated bearings and therefore does not
require oiling or lubrication.
Cleaning Exterior Parts
The molded plastic cover makes dry dusting quick and easy. If exterior parts
need to be cleaned use a mild soap and water solution. Be sure to unplug the
unit from its electrical supply before cleaning with soap and water.
Cleaning the Air Filter
The air filter is removable and washable. In order to re-
move the air filter the water bucket must first be removed.
Remove the air filter from the dehumidifier body by pulling
out and down on the filter frame. For best cleaning results
the filter should be washed in a mild soap solution and
water. Allow the air filter to dry before reinstalling.
stall the filter in the dehumidifier. Torn or ripped filters
should be replaced with a new filter.

Battery Replacement

Remove the battery cover on the top rear of remote (arrow indicates open
direction). Insert two, AAA batteries. Note position of positive (+) and
negative (-). Positioning the batteries in the wrong direction may cause
damage to the remote control. Re-insert cover. When batteries are installed
while the dehumidifier is plugged in, operation will begin.
Wall Mounting / Table Top - Remote Control
The remote control can be mounted to the wall with the bracket included with
the remote. Level bracket on surface to be mounted at convenient height. Mark
holes of bracket on wall surface. Obtain required hardware from hardware store
to fasten bracket to particular surface type. i.e. cement, drywall, paneling, etc.
Once mounted onto the surface, the rear portion of the remote has receiver holes
to clip onto the holder pins protruding from bracket.
For table top convenience, use the fold-out stand located on the back of the
hand-held remote.
Before Seeking Service Do These Simple Checks
Condition – Unit is Not Working
Is the dehumidifier connected to the electrical supply?
Has a fuse or circuit breaker blown? (check the outlet with another appliance)
Is the humidity control setting in a low enough position to operate?
Is the water container full and needs to be emptied?
Condition - Moisture Removal Seems Insufficient
1. Are the dehumidifier vents and air filter clear of obstructions and dirt?
2. Is there sufficient airflow around the unit for the location selected?
3. Is the humidity control set low enough for the desired results?
Important – Allow 3 minutes before turning the dehumidifier on after it
stops to allow all internal functions to reset.
This appliance complies with the suppression requirements of EEC directive 76/
889 + 82/499. Recommended limits of use: Temperatures: 5 to 35°C
Relative humidity: 30 to 80%.