ENGLISH
Klein Tools CL360 is an automatically ranging true root mean square
(TRMS) digital open jaw fork meter that measures AC current via the
fork, AC/DC voltage, continuity, and resistance via test-leads, and can
detect the presence of voltage via the integrated non-contact voltage
(NCV) tester.
• Operating Altitude: <6562 ft. (2000m)
• Relative Humidity: <80% non-condensing
• Operating Temp: 32° to 122°F (0° to 50°C)
• Storage Temp: -4° to 140°F (-20° to 60°C)
• Dimensions: 8.39" x 2.12" x 1.38" (213 x 54 x 35 mm)
• Weight: 7.3 oz. (208 g) including batteries
• Calibration: Accurate for one year
• Standards: IEC EN 61010-1, 61010-2-032, 61010-2-033.
• Accuracy: ± (% of reading + # of least significant digits)
Values stated at 65° to 83°F (18° to 28°C), Temp Coefficient:
0.1 x (Quoted Accuracy) per °C above 28°C or below 18°C,
corrections are required when ambient working temp is
outside of Accuracy Temp range
• Batteries: 2 x 1.5V AAA Alkaline (included)
• Drop Protection: 9.8 ft. (3m)
• Ingress Protection: IP40 dust resistant
• Pollution Degree: 2
• Safety Rating:
Jaw & Housing: CATIV 600V / CATIII 1000V
Electrical & Protection Circuit: CATIII 600V / CATII 1000V
Class 2, Double insulation
CAT II: Measurement Category II is applicable to test and measuring
circuits connected directly to utilization points (socket outlets and
similar points) of the low-voltage MAINS installation.
CAT III: Measurement category III is applicable to test and measuring
circuits connected to the distribution part of the building's low-
voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and measuring
circuits connected at the source of the building's low-voltage MAINS
installation.
• Electromagnetic Environment: IEC/EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
2
GENERAL SPECIFICATIONS
IEC EN 61326-1, 61326-2-2.
Conforms to: UL 61010-1, UL 61010-2-032,
UL 61010-2-033.
Certified to: CAN/CSA C22.2 NO. 61010-1,
61010-2-032, 61010-2-033.