Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instructions; Flow Diagram; Installation Example; En Instructions For Use / Assembly Instructions - HANSGROHE Axor Starck 10942000 Gebrauchsanleitung Und Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6
Safety Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
6 The product may not be used as a holding handle. A
separate handle must be installed.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.

Installation Instructions

• The fitting must be installed, flushed and tested after
the valid norms.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
• The premounted dirt collection screen must be used to
prevent dirt from entering through the pipes. Dirt enter-
ing can affect the function and/or lead to damage to
the functional components of the fitting. Hansgrohe
will not be held liable for any resulting damage.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
4
English
Symbol description
max. 0,6 MPa
0,1 - 0,4 MPa
1,6 MPa
max. 60 °C
Assembly see page 40
Do not use silicone containing acetic acid!
Dimensions (see page 31)

Flow diagram

(see page 33)

Installation example

(see page 32)
Warm water
Cold water
The wall must be reinforced in this
area.
Plug the unused outlet.
Cleaning (see page 44) and en-
closed brochure
Spare parts (see page 46)