• P osition the seat cover upright on a suitable seat with a sitting area and backrest (chair, sofa or
similar). Make sure that the seat has a sufficiently high backrest.
• U se the flexible fastening straps and Velcro strips to secure the Shiatsu seat cover.
• Connect the device to the mains by plugging the plug into the socket.

7. Operation

Gently press your back against the massage device to start with. Then make sure that you are in a comfort-
able position before gradually shifting your weight onto the massage device.The massage must be pleasant
and relaxing at all times. Stop the massage or change your position or the contact pressure if you find it is
painful or unpleasant.
• D o not force or jam any part of your body, in particular your fingers, between the rotating massage elements
or their holders in the unit.
• S it comfortably and upright on the seat cover. Ensure you sit centered and such that the massage heads
can move to the left and right of your spinal column.
• Switch on the massager with the button.
The LEDs signal the massage functions which are currently selected.
You can specify the settings as follows:
1. Demo run: Press the demo button to begin a quick 5-minute run-through of the functions contained in
the device. The manual controller indicates which function is being displayed by flashing the respective
LED. The device switches off automatically once the demo run has finished.
2. shiatsu neck massage
Press the A button to start the neck massage. Press it again to change the massage direction. Press the
button once more to end the neck massage.
3. shiatsu back massage
Press the SHIATSU button. Select the desired massage region with B + C, B and C.
spot massage, i.e. Shiatsu massage without vertical movement, can be selected by pressing one of the
two SPOT buttons. The position of the localised massage can be changed by pressing and holding one
of the two SPOT buttons until the desired position is reached.
Massage intensity
When using the Shiatsu Massage, two different massage speeds are available, which can be selected us-
ing the SPEED button. If you have the rolling massage activated, first press the SHIATSU button in order
to change to Shiatsu Massage and then set the desired massage speed.
4. rolling massage
Press the ROLLING button. Select the desired massage region with B + C, B and C.
When the massage type (Shiatsu or rolling massage) is changed, the preselected region (full, upper, lower
back) is retained. Note that the massage region must be selected again when switching from localised
Shiatsu massage to rolling massage.
5. heating function
Press the HEAT button to switch on the heating function of the massage heads. The blue lights in the
massage heads change colour to red.
• Do not use the massage device for longer than 15 minutes and then allow it to cool. Using the device
for longer can over-stimulate the muscles and cause tension instead of relaxation. The massage can be
finished at any time by pressing the button. Please note that on switching off, the massage heads first
return to the starting position at the lumbar region. This is indicated by the LED flashing. Once this position
is reached, the device switches off.
• If the device is stopped be pressing a massage area button twice, it also returns to the starting position
after 15 minutes and then switches off.
• Do not disconnect the device from the mains supply during operation. Always switch it off first and wait
until it has returned to the initial position.