- GB -
Pos: 27 /Alle Produkte/Länderkennzeichen/02===GB===1. Sprache @ 4\mod_1155109065198_0.doc @ 23181 @
-
GB
-
Pos: 28 /Alle Produkte/Überschriften/H1 Hinweise zu dieser Gebrauchsanleitung @ 10\mod_1248768026340_121.doc @ 66253 @
Information about these operating instructions
Pos: 29 /Alle Produkte/Hinweise zur Anleitung @ 10\mod_1248768082959_121.doc @ 66222 @
Welcome to OASE Living Water. You made a good choice with the purchase of BioPress.
Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit.
Ensure that all work with this unit is only carried out in accordance with these instructions.
Adhere to the safety information for the correct and safe use of the unit.
Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new
owner.
Pos: 30 /Filter/BioPress 6000/10000/Bestimmungsgemäße Verwendung BioPress 6000/10000 @ 10\mod_1248785287591_121.doc @ 66713 @
Intended use
The BioPress 6000/10000 series, in the following text termed unit, is an enclosed pressure filter system with integrated
UVC clarifying unit for the bio-mechanical filtering of normal pond water at temperatures from + 4°C to + 35 °C. The
pressure filter system is only suitable for private use and must exclusively be used for cleaning garden ponds with or
without fish population. The pressure filter system may only be operated with the supplied filter pump.
Pos: 31 /Alle Produkte/Überschriften/H1 Nicht bestimmungsgemäße Verwendung @ 7\mod_1204017506555_121.doc @ 44514 @
Use other than that intended
Pos: 32 /Alle Produkte/Nicht bestimmungsgemäße Verwendung - Gerät @ 7\mod_1204017770961_121.doc @ 44566 @
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and in the case of
misuse. If used for purposes other than that intended, our warranty and operating permit will become null and void.
Pos: 33 /Alle Produkte/Überschriften/H1 Sicherheitshinweise @ 6\mod_1196353926316_121.doc @ 40981 @
Safety information
Pos: 34 /Alle Produkte/Sicherheit/Einleitung/SIC 1 Sicherheitshinweise Einleitung @ 7\mod_1205310799730_121.doc @ 45453 @
The company OASE has built this unit according to the state of the art and the valid safety regulations. Despite the
above, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accor-
dance with its intended use, or if the safety instructions are ignored.
Pos: 35 /Alle Produkte/Sicherheit/Einleitung/SIC 2 Kinder und Jugendliche unter 16 Jahren @ 10\mod_1248435245769_121.doc @ 65253 @
For safety reasons, children and young persons under 16 years of age as well as persons who cannot re-
cognise possible danger or who are not familiar with these operating instructions, are not permitted to use the
unit.
Pos: 36 /Filter/PondoClear Set/Die Kombination von Wasser und Elek. PondoClear @ 2\mod_1137142911101_121.doc @ 12900 @
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly connected or
misused.
Attention! Dangerous ultra-violet radiation.
The radiation of the UVC lamp is dangerous to eyes and skin! For this reason, the unit can only be switched on with
the housing fitted (safety switch). Never operate the unit lamp outside of its housing. Never immerse the filter in water!
Always disconnect the power supply of these and all other units located in water prior to performing work on the units!
Only operate the units when plugged into an earthed socket. The latter must have been installed in accordance with
the valid national regulations. Ensure that the protective earth wire is led to the unit. Only use cables approved for
outside use. Never use installations, adapters, extension or connection cables without protective earth contact! The
cross section of power connection cables must not be smaller than the rubber cables identified with H05 RNF. Exten-
sion cables must meet DIN VDE 0620. Ensure that the units are supplied with a rated residual current of max. 30 mA
via a residual current-operating system (FI or RCD resp.). Electrical installations at garden ponds and swimming pools
must meet the international and national regulations valid for installers. Compare the electrical values of the power
supply with those on the type plate on the packaging or on the units. Protect the connection cable when burying to
avoid damage. Protect the plug connections and all connection points from moisture. Never operate the unit if the
cable or housing are defective! Disconnect the power! The power connection cables of these units cannot be replaced.
Replace the units (unit components) concerned if the cables are damaged. Do not carry or pull the units by their
connection cables. Never open the unit housings or their attendant components, unless this is explicitly mentioned in
the operating instructions. Never carry out technical changes to the units. Only use original spare parts and accesso-
ries for the units. Only allow authorised customer service outlets to perform repairs. For your own safety, consult a
qualified electrician if you have questions or encounter problems! Do not operate the units if persons are in the water!
Never run the units without water! Never use the pump for fluids other than water! Ensure that no leaks at the filter can
occur. Danger of completely emptying the pond.
Pos: 37 /Filter/Biopress 8000/12000/Montage BioPress 8000/12000 @ 5\mod_1161006361082_121.doc @ 28179 @
Installation (A)
Oase recommends hoses suitable for a minimum pressure of 1 bar.
Cut the stepped hose adapters such that the connection opening coincides with the hose diameter (A1). This helps to
avoid pressure loss.
At the filter, push the union nuts over the stepped hose connections, push or turn on the stepped hose connection, and
secure with the hose clips. Place the flat sealing rings in the union nuts and screw onto the inlet and outlet of the
pressure filter (A2). At the filter pump, push or turn the hose onto the stepped hose connection, secure with hose clips
and screw onto the filter pump connection thread (A3).
Pos: 38 /Filter/BioPress 6000/10000/Aufstellen BioPress 6000-10000 @ 10\mod_1250166201031_121.doc @ 69113 @
Installation (B)
Place the pressure filter in a flood protected position at a distance from the pond edge of at least 2m on firm and level
ground. As an alternative, the filter can also be partly buried up to approx. 5 cm below the closing clamps. Note the
maximum operating pressure of 0.2 bar. The height difference between the filter lid and the free outlet point may be
max. 2 m. Do not expose the unit to direct sun radiation. Ensure unobstructed access to the lid to be able to carry out
work at the unit. Place the filter pump in the pond as horizontal as possible on a firm, sludge free ground so that it is
completely in the water, at a maximum depth of 2 m below the water level.
8