Herunterladen Inhalt Inhalt Diese Seite drucken

Set Black Mark Sensor As Media Sensor And Calibrate The Black; Set Gap Sensor As Media Sensor And Calibrate The Gap Sensor; Skip Auto.bas - Schilling SP100+ Gesamt-Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SP100+:
Inhaltsverzeichnis

Werbung

4.4 Set Black Mark Sensor as Media Sensor and
Calibrate the Black Mark Sensor
Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green/amber after 5 green blinks. (Any
green/amber will do during the 5 blinks).
The LED color will be changed as following:
Amber
green/amber (5 blinks)
4.5 Set Gap Sensor as Media Sensor and Calibrate the
Gap Sensor
Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns red/amber after 5 green/amber blinks.
(Any red/amber will do during the 5 blinks).
The LED color will be changed as following:
Amber
green/amber (5 blinks)

4.6 Skip AUTO.BAS

TSPL2 programming language allows user to download an auto execution file
to flash memory. Printer will run the AUTO.BAS program immediately when
turning on printer power. The AUTO.BAS program can be interrupted without
running the program by the power-on utility.
Please follow the procedures below to skip an AUTO.BAS program.
red (5 blinks)
amber (5 blinks)
red/amber (5 blinks)
red (5 blinks)
amber (5 blinks)
red/amber (5 blinks)
green (5 blinks)
green (5 blinks)
27
solid green
solid green

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis