a good earth point having a large surface area
for minimum impedance.
The unit should be positioned well away from
cables with interference; if necessary a protective
screen or metal housing must be provided. The
running of wiring parallel to the mains supply
should be avoided.
Contactor coils must be linked with spark sup-
pression.
The running of wiring parallel to the mains supply
should be avoided.
Metallic components of the transmitter housing
should be earthed according to local regulations
and should not be connected potential free.
Power supply
Supply voltage is indicated in the delivery docu-
mentation and on the identification plate.
Power supply ≤ 30VDC
Load capacity < 1W
4.1 Pin assignment
Potentiometer 8 pole plug pin.
Pin
Designation
Potentiometer 1
1
Po
Start point
2
- - -
3
- - -
4
- - -
5
- - -
6
Pe
End point
7
S
Moving contact
8
- - -
5. Adjusment and alignement
5.1 Potentiometer setting
When correctly connected and switched on, the
unit displays the current actual value.
SG32
Datum 10.06.2010
viewing side = plug-in-side
Designation
Potentiometer 2
- - -
Po
Start point
S
Moving contact
Pe
End point
- - -
- - -
- - -
- - -
Rs = Series impedance
R = Potentiometer
The measuring range of the potentiometer is mat-
ched to the total pull-out length of the wire. Ex
works the potentiometers is adjusted to lowest
value for extension length 0mm (ie. for fully re-
traced wire).
6. Starting
Please ensure that the instructions given in chap-
ter 4 regarding mechanical and electrical connec-
tion are followed. This will ensure correct installa-
tion and the operating reliability of the device.
Before starting check again:
correct polarity of the supply voltage
correct cable connection
correct mounting of the device

7. Accessory connector

Available from SIKO as accessory art.no. 83525.
Wire cross section is to be at least max. 0,5mm².
Cable channel: 6-8mm.
Please proceed as follows (see fig. 8):
Fig. 8: Counter-plug
1.
Mount seal to screen ring (4).
2.
Slip parts 1 ... 6 over outer cable.
3.
Dismantle cable (35mm), strip (4mm) and tin
conductor.
4.
Shorten (except for 6mm) and turn down
screen.
5.
Screw wires into socket (7) (follow connection
diagram).
6.
Mount parts 2 ... 6. Place screen around screen
ring (4).
7.
Screw pressing screw (1) and coupling sleeve(5)
together.
Art.Nr. 85391
Änd. Stand 151/10
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis