6.7
Nominal power consumption at A7/W35 / max. consumption
Nominal current at A7/W35 / cos 
6.8
6.9
Power consumption of compressor protection
(per compressor)
6.10 Power consumption of fan
7
Complies with the European safety regulations
8
Additional model features
8.1
Type of defrosting
8.2
Condensate tray frost protection /
water in device is protected from freezing
8.3
Max. operating overpressure (heat source/heat sink)
9
Heat output / coefficient of performance (COP)
9.1
Heat output / coefficient of performance (COP)
9.2
Cooling capacity / coefficient of performance (COP)
1. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can increase by up to 3 dB (A).
2. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation at A7/W35; 67 Hz (LAW 9IMR) / 58 Hz (LAW 14ITR).
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A) depending on the installation location
3. Please note that additional space is required for pipe connections, operation and maintenance.
4. Delivery state 6 kW
5. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and operation
can be found in the respective sections of the installation and operating instructions. For example, A 7 / W35 means heat source temperature 7 °C and heating water flow temper-
ature 35 °C
6. See CE declaration of conformity
7. The heat circulating pump and the heat pump manager must always be ready for operation.
8. 2 compressor operating mode
9. 1 compressor operating mode
www.dimplex.de
5
kW
A / --
W
W
7
bar
5
8
at A-7 / W35
kW / ---
9
kW / ---
8
at A2 / W35
kW / ---
9
kW / ---
8
at A7 / W35
kW / ---
9
kW / ---
8
at A7 / W45
kW / ---
9
kW / ---
8
at A10 / W35
kW / ---
9
kW / ---
8
at A27 / W9
kW / ---
9
at A27 / W7
kW / ---
8
at A27 / W18
kW / ---
9
kW / ---
8
at A35 / W9
kW / ---
9
at A35 / W7
kW / ---
8
at A35 / W18
kW / ---
9
kW / ---
452162.66.04 · FD 9303
LAW 9IMR - LAW 14ITR
2,11
9,27 / 0,99
--
124
6
Reverse circulation
No / Yes
3,0
EN 14511
7,1 / 2,8
6,2 / 3,2
8,9 / 4,3
8,3 / 3,3
9,6 / 4,5
6,5 / 3,3
8,7 / 4,2
6,2 / 2,6
9,0 / 3,4
3,39
4,94 / 0,99
--
248
6
Reverse circulation
Yes/ Yes
3,0
EN 14511
13,7 / 2,7
11,0 / 3,2
14,7 / 4,3
13,9 / 3,3
15,7 / 4,3
12,9 / 3,0
17,1 / 3,7
12,3 / 2,5
15,5 / 3,3
EN-19