Day of regeneration
Note:
The display shows "dX Y" where X is the day of the week (1-7) and Y shows whether the selected day is enabled
for regeneration "1" or not, "0".
H
Select the day with
The days with enabled regeneration flash.
I
Press
to validate the selection and advance to the next parameter.
Time of regeneration
J
Adjust the time of regeneration with
Time flashes.
K
Press
to validate the selection.
"End" appears on the screen, programming is now complete.
4.2.
History
To access the recorded information, press and hold
5 .

Operation

5.1.
Recommendations
• Use only regenerate salts designed for water softening EN973;
• for optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets);
• do not use ice melt, block, or rock salts;
• the sanitizing process (both with liquid and electrochlorination) introduces chlorine elements which may reduce the lifetime
of the ion exchange resins. Refer to the technical guides for resins in common use, providing necessary checks on the
system.
5.2.
Manual regeneration
Immediate regeneration
A
Press and hold
for 5 seconds.
Regeneration icon displayed.
Camshaft starts rotating to cycle C1.
6 .

Error messages

The following error messages may be displayed during operation:
Note:
Salt alarm, the brine tank is empty. Press any key to acknowledge this alarm and reset the salt alarm
counter to the programmed value. No regenerations are carried out during the salt alarm.
Refill the brine tank with salt.
Note:
Microswitch alarm. The module cannot find the service position. No regenerations are carried out
during the microswitch alarm.
Call your local dealer. See 8 . Troubleshooting, page 7.
7 .

Maintenance

Mandatory:
Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper
functioning of the complete system, and be documented in the Maintenance record book.
Mandatory:
The maintenance must be done by a professional certified by Pentair, otherwise the warranty will void.
8 .

Troubleshooting

Please follow this procedure for any technical support:
A
Collect the required information for a technical assistance request.
Product identification (see 2.1. Serial label location, page 5 and Original settings, page 2);
Error number displayed on the controller;
B
Contact your local dealer who installed this device (see contact details on last page).
Also call him if the water tastes salty, if the water is not softened or if there is no salt consumption.
Ref. MKT-UG-003 / B - 26.06.2018
and enable or disable the regeneration with
and
.
.
for 5 seconds.
User Guide Siata V132-SFE
7 / 36