Herunterladen Diese Seite drucken

E - Recommendations For Energy Saving; Maintenance; A - Discharging Condensation - Olimpia splendid DOLCECLIMA AIR PRO Hinweise Für Die Verwendung Und Pflege

Vorschau ausblenden Andere Handbücher für DOLCECLIMA AIR PRO:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 115
c. Make sure the filter (30) has dried completely.
d. Correctly reposition the filter (30) in its specific seat (Fig. 25).
e. Suck possible fluff from the grille (Fig. 25).
Do not use the appliance without the filter (30).

4.1.e - RECOMMENDATIONS FOR ENERGY SAVING

Below find simple recommendations for reducing consumption:
• Always and constantly keep the filters clean (see maintenance and cleaning chapter).
• Keep the doors and windows of the rooms to be climate controlled closed.
• do not let sun rays penetrate freely into the room (we recommend using curtains or lowering blinds or
closing the shutters).
• Do not obstruct the air flow path (input and output) of the appliance; this, in addition to obtaining a non-op-
timal yield, also affects the correct operation of the appliance and the possibility of irreparable damages to
the appliance itself.

4.2 - MAINTENANCE

if you do not intend to use the appliance for a long period of time, work as follows:
a. activate the fan only mode for a few hours (approximately 8÷10 hours) to dry the interior of the appliance.
b. Stop the air conditioner and disconnect the power supply.
c. Clean the air filters.
d. Completely discharge condensation.
e. Wrap the power supply cable (34) around the cable winder (33) and insert the plug in the specific housing
(31) (fig.31).
f. remove the batteries from the remote control.
Checks before resuming use of the air conditioner:
a. Clean the filters after a long period of inactivity of the air conditioner.
b. Check that the air outlet or inlet are not obstructed (especially after a long period of inactivity of the air
conditioner).

4.2.a - Discharging condensation

When condensation in the lower tray reaches the predetermined level, the appliance emits 8 beeps; "P1"
appears on the control panel and the appliance stops working (the fan motor keeps running).
in this case:
a. disconnect the plug from the power socket.
b. Carefully move the appliance in position suitable to unload water.
c. remove the drain cap (32) and the rubber cap (32a) (fig.26).
Make sure you correctly tightened the drain cap (32) in order to avoid water leak.
d. make water unload completely.
e. reposition the rubber cap (32a) and screw the drain cap (32) (fig.27).
f. insert the plug in the power socket and restart the machine until when the indicator "P1" turns off.
If the error repeats, please contact an Assistance Centre.
EN - 31
DOLCECLIMA AIR PRO

Quicklinks ausblenden:

Werbung

loading