INSTALLATION
The hood may be in filtering or in ducting
version (see A-B-C pag.2). Decide from
the outset which type is to be installed. For
better efficiency, we recommend installing
the hood in the ducting version (if possible).
FILTERING VERSION (A)
The hood purifies the air and
recycles the clean air backb into the
room. For this version, the following
is required: a theft-proof cover, a
reducer and charcoal filter. In the
version with flue, the upper flue
must have the air evacuation slots
positioned in the upper part and
the deflector must be used in place
of the anti-theft cover. The upper
flue air evacuation slots must be
positioned at the top.
DUCTING VERSION (B) (C)
The hood purifies the air and
evacuates it to the outside through
an exhaust duct or hole (diameter
150 mm).
Roof Venting (B)
Wall Venting (C)
AIR VENT
(for ducting versions)
! Prepare the hole and the air vent duct
(150 mm diameter - not provided with the
product).
! Use a duct of the minimum indispensible
length.
! Use a duct with as few elbows as possible
(maximum elbow angle: 90°).
! Avoid drastic changes in the duct cross-
section.
! Use a duct with an as smooth as possible
inside.
! The duct must be made of certified
material.
! Do not connect the hood to smoke exhaust
ducts for the products of combustion
(boilers, fireplaces, stoves, etc).
! For the air vents comply with the provisions
en
es
laid down by the competent authorities. In
addition, the air must not be evacuated
through a hole in the wall unless specifically
intended for this purpose.
! Fit air intakes in the room to prevent the
hood from creating a negative pressure
in the room (which must not exceed 0.04
mbar); if the hood is used at the same time
as non-electrical equipment (gas-, oil- and
charcoal-fired stoves, etc.) the exhaust
gas may be sucked in by the heat source.
ASSEMBLY
! WARNING: Very heavy product; hood
handling and installation must be carried
out by at least two persons.
! WARNING: Wear gloves and goggles
when
carrying
maintenance operations.
! WARNING: Failure to install the screws
or fixing device in accordance with
these instructions may result in electrical
hazards.
! The minimum distance between the
supporting
equipment on the hob and the lowest
part of the range hood must be not less
than 45cm from electric cookers and
45cm from gas or mixed cookers. If the
instructions for installation for the gas hob
specify a greater distance, this must be
adhered to.
! Expansion wall plugs are provided to
secure the hood to most types of walls/
ceilings. However, a qualified technician
must verify suitability of the materials in
accordance with the type of wall/ceiling.
The wall/ceiling must be strong enough to
take the weight of the hood. Do not tile,
grout or silicone.
! In case of doubt, consult an authorised
service assistance centre or similar
qualified person.
For installation instructions refer to
figures at pag. 2/10
17
17
out
installation
surface
for
the
and
cooking