8
2
Installing the terminal boxes
The best way to fit the VKK... terminal boxes is with the grommets pointing
downward. This makes it more difficult for moisture to get in.
2.1
Mounting dimensions VKK1-4 / VKK1R-4
Suitable fastening screws: M4 DIN 84 or B3.9 DIN 7971 (minimum screw length 20 mm)
Fig. 2.1: Mounting dimensions of the VKK1-4
Mounting direction
Fig. 2.2: Mounting dimensions of the VKK1R-4
HBM
179
163
Mounting direction
∅ 4...6.5
186
176
204
190
VKK1-4 / VKK1R-4
SW14
*
depending on the cable type
Grounding screw
M5x10 DIN 84
M4
5x M12, SW14,
for cable ∅ 4 ... 6,5 mm
30
110
100
125
A2326-1.1 en/de/fr