11. Troubleshooting

Fault
The tool is blocking during the
operation, or the welding
process, due to this fact it isn't
possible to extract the tool from
the strap.
Li-Ion battery plugged into tool,
but the tool doesn't work.
Progressive abatement of Li-Ion
battery duty cycles.
Charger does not start charging
and/or flashes red.
Work parameters like tensioning
force and welding time cannot
be entered and/or do not remain
saved.
Pressing the push-button 2
doesn't start the welding
operation.
TA750
(0001)
Cause
The sealing mechanic is
blocking.
Li-Ion battery defective or
insufficiently charged.
Contacts of Li-Ion battery or the
tool polluted or defective.
Loose cable connections.
Li-Ion battery defective or
insufficiently charged.
Life of Li-Ion battery moves
towards its end, internal cells
are defective or exhausted.
Contacts of Li-Ion battery or the
tool, polluted or defective.
Mains plug of the charger isn't in
the socket, or charger is
defective.
Li-Ion battery is defective.
Circuit board (120) or circuit
board control (117) is defective.
Push-button 2 (109), welding
motor (503) and/or circuit board
(120) defective, or loose cable
connection.
H TA750 EU 46/17
Remedy
Remove and reinsert the Li-Ion
battery straight. The blockade
should be dissolved because the
control system moves the sealing
mechanism in basic position.
Should the fault not have been
remedied, contact TITAN service
dept.
Check charge of Li-Ion battery and
recharge or, if required, replace it.
Visual inspection of the contacts;
clean and straighten them, if
required.
Check the cable connections and fix
them if required.
Check charge of Li-Ion battery and
recharge or, if required, replace it.
Then use the charged Li-Ion battery
again and check (count) if there is
an improved cycle time.
Use new Li-Ion battery.
Visual inspection of the contacts;
clean and straighten them, if
required.
Check if the mains plug is in the
socket, and put the socket in if
required. Check charger for
function.
Do not use the Li-Po storage battery
any further and replace it with a new
Li-Po storage battery.
Contact TITAN – Service.
Visual check for loosen cable
connection, re-establish the cable
connection if required. Contact
TITAN-Service.