10) REPLACING THE INJECTORS
The burners can be adapted to different types of
gas by mounting injectors suited to the type of gas
in question. To do this, first remove the burner tops
using a wrench "B". Now unscrew injector "A" (see
fig. 13) and fit a injector corresponding to the
utilized type of gas in its place.
It is advisable to strongly tighten the injector in
place.
After the injectors have been replaced, the
burners must be regulated as explained in
BURNERS
N°
DESCRIPTION
2
RAPID
5
AUXILIARY
BURNER ARRANGEMENT ON THE HOT PLATE
GAS
G30 - BUTANE
G31 - PROPANE
G20 - NATURAL
G25 - NATURAL
G30 - BUTANE
G31 - PROPANE
G20 - NATURAL
G25 - NATURAL
CONVERSIONS
paragraphs 8. The technician must reset any
seals on the regulating or pre-regulating
devices and affix the label corresponding to the
new gas regulation on the appliance instead of
the already existing one. This label is supplied
in the packet containing the spare injectors.
For the sake of convenience, the nominal rate table
also lists the heat inputs of the burners, the
diameter of the injectors and the working pressures
of the various types of gas.
NORMAL
NORMAL
RATE
PRESSURE
mbar
g/h
l/h
50
204
50
200
20
267
20
310
50
73
50
71
20
95
20
111
FIG. 13
28
INJECTOR
NOMINAL HEAT
DIAMETER
INPUT (W)
1/100 mm
Min.
72 M
900
72 M
900
117 Y
750
133 F3
750
46 M
500
46 M
500
75 X
400
78 F1
400
BY PASS
Max. 1/100 mm
2800
41
2800
41
2800
Adj.
2800
Adj.
1000
30
1000
30
1000
Adj.
1000
Adj.