Technical Data

TechniRouter
Article number
Return path, terrestrial: 5..790 MHz
Satellite:
0.95 ... 2.15 GHz
Number of trunk inputs
Number of trunk outputs
Number of subscriber cables
Subscriber per cable
Subscriber number and
receiving channels
(User bands)
Trunk loss
Gain of the subscriber signals
Reflection loss
Isolation
Trunks
Subscriber
Input level, satellite signal
recommended
= ˆ
minimum (
sensitivity)
maximum
Phase noise
Power supply
Power requirement
in operation
receiver off
with LNB
(200 mA)
∅ p.a.
Control by the receiver
Special features
Screening attenuation
Environmental conditions
Accessories
deployable in the trunk
deployable in the
subscriber line
Dimensions l x w x h(mm),weight
1)
Values at the lower ... upper band limits
2)
All other trunk and subscriber lines with signal
3)
Conforming to EN 60728-3: namely IMA3 at the output: 35 dB
5 / 1x8 G
5 / 1x8 K
0000/ 3290
0000/ 3291
RW /
RW /
Sat.
Terr.
Terr.
1
4
1
1
1
maximum 8
maximum 8
channel 1 : 1284 MHz
channel 2 : 1400 MHz
channel 3 : 1516 MHz
channel 4 : 1632 MHz
channel 5 : 1748 MHz
channel 6 : 1864 MHz
channel 7 : 1980 MHz
channel 8 : 2096 MHz
2...3
dB
13...18
-1 dB
-8 dB
dB
40 ... 35 dBµV, although the subscriber cables, depending on
length, must be supplied with far higher levels.
-60 dBc/Hz (SSB @ Δf = 1 kHz from the carrier)
TechniRouter & LNB are supplied from the receivers, optional for LNB:
wall power supply 230 V / 13V, 460 mA DC,short and overload protected
Maximum 5 W / 410 mA from the receiver
0 W without power supply / 3 W with power supply
Depending on TV habits, Benchmark 10 kWh (without power supply)
DiSEqC-Protocol as per to EN 50494
Traffic indicator = installations aid, no power supply necessary
In accordance with EN 50083-2 (TechniSelect S)
-25...+55°C, Surge protection at inputs and outputs: < 5 kV, IP 50
Intermediate amplifier 5Z(2)/NT, (double) tap 5/2A, passive distributor 5P
loop through sockets with 10 dB or 13 dB tap loss, terminal socket
G : 150 x 114 x 43 , 0,4 kg
41
5 / 2x4 G
0000/3292
RW /
Sat.
Sat.
Terr.
4
1
4
1
2
maximum 4
channel 1 : 1284 MHz
channel 2 : 1400 MHz
channel 3 : 1516 MHz
channel 4 : 1632 MHz
1)
3 ... 5
dB
13...18
17...22
-5 dB
dB
dB
10 dB
45 dB 2)
30 dB
70 dBµV
3)
80 dBµV
= ˆ
Unicable, OLT, SCR or SCD
attenuator, splitter,
K : 150 x 123 x 43 , 0,4 kg
5 / 2x4 K
0000/3293
RW /
Sat.
Terr.
4
1
4
1
4
2
maximum 4
2...3
3...5
dB
dB
17...22
-12 dB
dB
EN