Herunterladen Inhalt Inhalt Diese Seite drucken

Operation And Maintenance - simu T5E Originalanleitung

Vorschau ausblenden Andere Handbücher für T5E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
4
Re-adjustment of end limits
4.1. Re-adjustment of down end limit:
In case of an automatic adjustment (with rigid link) the re-adjustment will also be automatic (every 60 cycles). In this case,
do not proceed to the following operations.
2
1
>>
1. Position the motor on the down end limit set in §2.5 using the ▼ key.
2. Press the ▼ key 6 times, each time for 6 seconds. After the 2
then the other*.
3. Position the motor on the new desired lower position using the ▲ and ▼ keys.
4. To confirm the new End Limit position, press ▲ twice, once for 0,5 second without the motor rotating and the second time
for at least 3 seconds, so the motor rotates briefly one way, then the other*.
4.2. Re-adjustment of up end limit:
In case of an automatic adjustment (with buttom slat stopper) the re-adjustment will also be automatic (every 60 cycles).
In this case, do not proceed to the following operations.
2
1
>>
1. Position the motor on the up end limit set in §2.6 using the ▲ key.
2. Press the ▲ key 6 times, each time for 6 seconds. After the 2
then the other*.
3. Position the motor on the new desired high position using the ▲ and ▼ keys.
4. To confirm the new End Limit position, press ▼ twice, once for 0,5 s without the motor rotation and the second time for at
least 3 seconds, so the motor rotates briefly one way and then in the other*.
5
Cancelling the end limits adjustment
- Connect the motor to the settings switch (§2.1)
- Press the ▲ and ▼ keys simultaneously, for at least 7 seconds. The motor rotates
one way, then the other*, then a few seconds later rotates in both directions*.
After this operation, the motor returns to its factory settings; repeat the operations from
chapter 2.
6

Operation and maintenance

- This drive is maintenance-free.
- Press the ▲ button on the control point to raise the motorised product.
- Press the ▼ button on the control point to lower the motorised product.
Tips and recommendations for use:
PROBLEMS
The motorised product does not operate. The overheating protection on the drive has been activated.
If the motorised product still does not work, contact a drive and home automation professional.
SIMU SAS, F-70103 GRAY as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz and used
as intended according to these instructions, is in compliance with the essential requirements of the applicable European Directives and in particular of the
Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU. The full text of the EU declaration of conformity is available at www.simu.com.
Emmanuel CARMIER, general director, GRAY, 11/2016
>>
>>
>>
>>
>>
>>
3
>>
>>
, 3
, 4
, 5
, and 6
press the motor rotates briefly one way,
nd
rd
th
th
th
3
>>
>>
, 3
, 4
, 5
, and 6
press the motor rotates briefly one way,
nd
rd
th
th
th
POSSIBLE CAUSES
4
+
6s max.
0,5s
>3s
4
+
6s max.
0,5s
>3s
>7s
>>
>>
2s
7s
SOLUTIONS
Wait for the drive to cool down.
3/3

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis