DESCRIPTION OF THE DEVICE

The PIEZOSURGERY
white is a device that
®
uses ultrasonic piezoelectric technology to
generate mechanical microvibrations of the
inserts (from 20 to 60 μm), to effectively cut
and safe cutting which preserves the integrity
of the osteotomized surfaces.
The micrometric, ultrasonic vibrations
of the inserts provide greater precision
and a selective cutting action compared
01.3

RESPONSIBILITY WAIVER

The manufacturer Mectron disclaim any
liability, expressed or implied, and shall have
no responsibility for any direct, indirect or
other damages and personal injury arising
out in connection with any practice in the
use of the device and its accessories.
The manufacturer Mectron shall be under no
liability, expressed or implied, with respect to
any damages (personal injury and/or damage
to property) which might arise or be caused,
whether by the customer or by any of the
users of the product and its accessories, as
result of:
1 Use or procedures different than those
product;
2 The environmental conditions for the
preservation and storage of the device
are not compliant to the precautions
indicated in the Chapter 08 - TECHNICAL
DATA;
3 The device is not used in compliance
with all the instructions and precautions
described in this manual;
01
INTRODUCTION
to traditional methods such as drills
or oscillating saws (which act with
macrovibrations), therefore minimizing
traumatic effect on soft tissues .
The cavitation effect of the irrigating solution
This provides an optimal intra-operatory
visual control thus increasing safety, even in
access.
4 The electrical system in the premises in
which the device is used is not compliant
to the norms in force and to the relative
precautions;
5 The assembly operations, extensions,
adjustments, updates, and repairs on the
device are performed by personnel not
authorized by Mectron;
6 Improper use, mistreatments, and/or
incorrect interventions;
7 Any and all attempts to tamper with
or modify the device, under any
circumstance;
8 Use of non-original Mectron inserts that
the handpiece, thus compromising correct
operation and causing risk of harm to the
patient:
9 Use of non-original Mectron inserts, used
in accordance to designed and tested
settings of Mectron original inserts. The
correct use of the settings is guaranteed
only with original Mectron inserts;
10 Lack of stock materials (handpiece,
inserts, wrenches) to be used in the
event of device stop due to fault or of
inconveniences.
EN
5