Original instructions
PA2500
ES
.... 35
PL
.... 60
FR
.... 40
RU
.... 65

Werbung

loading

Inhaltszusammenfassung für Frico PA2500

  • Seite 1 Original instructions PA2500 ..30 ..40 ..35 ..21 ..26 ..50 ..60 ..45 ..55 ..65...
  • Seite 2 PA2500 Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene...
  • Seite 3 PA2500 PA2500 1026 / 1536 / 2026 1026 / 1536 / 2026 1050 / 1560 / 2050 1050 / 1560 / 2050 90,5 min 500 90,5 min 500 Cu ø15 Cu ø15 min 500 min 500 min 500 min 500...
  • Seite 4 PA2500 TX20 Fig.3: Open the unit.
  • Seite 5 PA2500 Fig.4: Minimum distance.
  • Seite 6 PA2500 Mounting with wall brackets ø8 (3x) ø5 ø10 PA2510 2 pcs PA2515 2 pcs PA2520 3 pcs Fig. 6: Mounting with wall brackets...
  • Seite 7: Accessories

    PA2500 Accessories PA34TR15 PA2510, PA2515, 1 m PA34TR20 PA2520, 1 m PA2P15 PA2510, PA2515, 1 m PA2P20 PA2520, 1 m PA2PF15 PA2510, PA2515 PA2PF20 PA2520 PAMLK PA2500 PA34TR PA2PF PA2P PAMLK...
  • Seite 8 PA2500 Accessories SIRe SIReB SIReAC SIReAA SIReB SIReUR SIReRTX 673 09 22 70x33x23 mm SIReUR 673 09 21 114x70x50 mm SIReWTA SIReWTA SIReCJ4 SIReCJ6 SIReCC603 673 09 23 673 09 24 SIReCC605 SIReAC/SIReAA SIReCC610 673 09 25 10 m SIReCJ4/SIReCJ6...
  • Seite 9 PA2500 PA2510E05/ PA2515E08/ PA2520E10 SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Seite 10 PA2500 PA2510E08/ PA2515E12/ PA2520E16 SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Seite 11 PA2500 PA2510WA/ PA2515WA/ PA2520WA SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Seite 12 PA2500 PA2510E05YD/ PA2515E08YD SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Seite 13 PA2500 PA2520E10YD SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Seite 14 PA2500 PAMLK, motor alarm card SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo N F1 F2 F3...
  • Seite 15 PA2500 SIReB Basic PA2500 E SIReB2 SIReUB1 SIReRTX (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB Basic - Parallel connection SIReB2 SIReB2 SIReRTX SIReUB1 (optional) 230V~ 230V~ ROOM ROOM Pot. Pot. Unit ID Unit ID ACTUATOR SUPPLY ACTUATOR SUPPLY...
  • Seite 16 PA2500 SIReB Basic PA2500 W SIReB2 SD230 SIReRTx SIReUB1 (optional) ROOM 230V~ Pot. Unit ID ACTUATOR SUPPLY...
  • Seite 17 PA2500 SIReB Basic - Parallel connection PA2500 W SIReB2 SD30 ROOM 230V~ Pot. Unit ID ACTUATOR SUPPLY SIReB2 SD30 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB2 SD30 SIReUB1 SIReRTX (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY...
  • Seite 18 PA2500 Output charts water PA2500 Supply water temperature:110 °C Water temperature: 110/80 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output * Outlet Water Pressure position water flow drop air temp.
  • Seite 19 PA2500 Output charts water PA2500 Supply water temperature: 60 °C Water temperature: 60/40 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +32 °C Type Airflow Output Return Water Pressure Output * Outlet Water Pressure position water...
  • Seite 20 PA2500 Technical specifications |   3 PA2500 E with electrical heat ∆t Type Output Airflow Sound Voltage Amperage Voltage [V] Length Weight steps level* motor motor Amperage [A] [kW] [°C] [dB(A)] (heat) [mm] [kg] PA2510E05 1,7/3,3/5 900/1450 17/10,5 42/51 230V~...
  • Seite 21 Geräts entlang der Schiene in die Halterungsschlitze. (Abb. 6D) Ist die Halterung Einsatzbereich einmal gebogen worden, muss sie ersetzt Der PA2500 ist für Installationshöhen bis werden, sofern sie über 45° zurückgebogen zu 2,5 Metern geeignet. Der Luftschleier ist wird.
  • Seite 22 Beachten Sie, dass für das Gerät ein externen Einlassfilters (siehe Zubehörseiten) Regelventil vorgeschaltet sein muss, siehe empfohlen, der eine einfachere Wartung Ventilsatz von Frico. ermöglicht, da das Gerät nicht geöffnet Das Wasserheizregister wird an der werden muss. Sollte ein externer Filter Geräteoberseite mithilfe eines glatten...
  • Seite 23 PA2500 Service, Reparaturen und Wartung Überhitzung Vor jedem Service, Reparatur oder Wartung Der Luftschleier mit elektrischer Heizung ist Folgendes ausführen: mit einem Überhitzungsschutz ausgestattet. Sollte er aufgrund von Überhitzung ausgelöst 1. Die Stromversorgung trennen. werden, setzen Sie ihn wie folgt zurück: 2.
  • Seite 24: Sicherheit

    PA2500 Entleeren des Heizregisters (W) FI-Schalter (E) Die Ablassventile befinden sich unten am Sollte die Installation durch einen FI- Heizregister an der Anschlussseite. Sie Schalter geschützt sein, die beim Anschließen können über die Frontklappe erreicht werden. des Geräts ausgelöst wird, kann dies mit der Feuchtigkeit im Heizelement zusammenhängen.
  • Seite 25 Airflow [m Luchtstroom Output* [kW] Leistung Return water temperature [°C] Rücklaufwassertemperatur Water flow [l/s] Wassermenge Pressure drop [kPa] Druckverlust ) Empfohlene Ausblastemperatur für angenehmen Komfort und optimale Leistung. ) Nennleistung bei angegebener Vor- und Rücklaufwassertemperatur. Weitere Berechnungen finden Sie auf www.frico.se.
  • Seite 28 Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 Fax: +46 31 26 28 25 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...