VISUAL AND SOUND ALARMS
BLINKER
N.B.: This control panel can power ONLY BLINKERS WITH BLINKING CIRCUIT (ACG7061) with
lamps up to 24V and 20W.
PRE-BLINKING
DIP 5 - OFF => motor and blinker start simultaneously.
DIP 5 - ON => blinker starts 3 seconds before the motor.
BUZZER
It has the task to signal the intervention of the security, the anomalies and the memorization
and cancellation of the radio codes.
SIGNAL - 24Vdc GATE OPEN WARNING LIGHT (COM A+/SIGNAL-)
Signals when the gate is open, partially open or not closed completely. It turns off only when
the gate is completely closed.
During opening, it flashes slowly.
When the gate is stationary or opened, it is permanently on.
During closing, it flashes quickly
N.B.: Max 3 W. If warning lights are in excess, the control panel processes will be
endangered with possible stop of all operations.
OPERATION AFTER A BLACK-OUT (WITHOUT BATTERIES)
When the power supply comes back the DL1 led turns on and remains on for all the time the
gate stays open. The led will turn off only once the gate is completely closed.
It is recommended to fully open the gate. Let the gate close by itself or with automatic closing,
or wait until the blinker stops flashing before commanding it to close.
This will allow the gate to realign. If, motors were released and moved from the normal
position when closed during the blackout, the first movement after power returns must be
complete.
If the black out occurs when the gate is still moving or when the gate is open and the first
command sent after the black out is a closing command, the closing of the gate will be
carried out with a total delay between the two gate leaves. Therefore, first the leaf M2 will
close completely; once it is off, M1 will start closing. This separate movement of the two gate
leaves is done to avoid their incorrect overlapping.

TECHNICAL SPECIFICATIONS

- Temperature range
- Humidity
- Voltage
- Frequency
- Battery power
- Transformer Power
- Maximum absorption
- Power supply microinterruptions
- Maximum power SIGNAL output
- Maximum blinker power
- Power for photocells and accessories 1 A ± 15 %
- Power for radio connector
RADIO SPECIFICATIONS (model B2 24V-CRX)
- Reception frequency
433,92 MHz
- Impedence
52 ohm
- Sensitivity
>1 µV
- Feedback control
PLL
- Memory storage (codes)
1000
- All inputs must be used as clean contacts because the power is generated internally (secure
power) to the board and is set up to ensure compliance with double or reinforced insulation
with regard to dangerous voltage.
- Any external circuits connected to the outputs of the control panel must be made in such
a manner as to ensure compliance with double or reinforced insulation with regard to
dangerous voltage.
- All inputs are controlled by a programmed integrated circuit that performs a self check every
time it starts operating.
0 ÷ 55 °C
< 95 % without condensation
230 V~ ± 10% (120 V 60 Hz upon request)
50/60 Hz
20-24 Vdc
130 VA - primary 230 Vac - secondary 18 Vac
25 mA
100ms
24 Vdc 3 W (equivalent to one 3W or 5 LED light
bulb with resistor in series at 2.2 K ohm)
24 Vdc 20 W
200 mA
43
G
B