5. Operation
< Process for setting >
[1] To turn off air conditioner and change the remote
controller to "Fixed airflow direction mode"
1.Press ON/OFF button 1 to turn off the air conditioner.
.Press Fan Speed button 2 and Filter
seconds simultaneously and it becomes the fixed airflow direction
mode after a while.
"Fixed airflow direction mode" display
Air blows downward after it becomes
"fixed airflow direction mode".
[2] To select and identify the outlet to set
1.Press Set Temperature button 5 to change number with the outlet No.
blinking. Select outlet No. to set.
Unit No.
Up/Down air direction Refrigerant address No.
Outlet No.
Outlet No.3
Outlet No.2
.Press Filter
button 3 to send the information on remote controller.
3. Wait for 15 seconds. How does the air conditioner run?
→Only the air from the selected outlet blows downward.
→Go to step[3].
→Air from the wrong outlet blows downward.
→Repeat 1 and set again.
→All outlets are closed.
→The numbers of the air conditioner (refrigerant address No.,
Unit No.) are wrong. Refer to How to find air conditioner No..
[3] To fix air direction
1.Press Mode button (Return button) 4 to blink Up/Down air direction
indicater.
.Press Set Temperature button 5 until the direction to set is chosen.
3.Press Filter
button 3 to send the information on remote controller to
air conditioner.
4.Wait for 15 seconds. How does the air conditioner run?
→Airflow direction is set in the selected direction.
→The fixed setting completed (Go to step [4].)
→Airflow direction is set in the wrong direction.
→Repeat 2. and set again.
Up/Down air direction
Unit No.
Outlet No.
Air direction changes
This indicates NO FIXED SETTING(canceled)
8
button 3 for more than 
Outlet No.4
MITSUBISHI
ELECTRIC
label
Outlet No.1
Note: "0" indicates
all outlets.
Refrigerant address No.
[4] To cancel "Fixed airflow direction mode"
1.Press ON/OFF button 1 to cancel "Fixed airflow direction mode".
It is also canceled by pressing Fan Speed button 2 and Filter
3 for more than  seconds simultaneously.
2.Do not operate remote controller for 30 seconds after the "Fixed airflow
direction mode" is canceled. It does not accept even if it is operated.