Technical Data
Device description acc. to 94/9/EC
Device description acc. to 94/9/EC
Electromagnetic compatibility
Typ XTR 0000, XTR 0001, XTR 0090 and
XTR 0091 with sensing head SE Ex PR M:
Typ XTR 0010, XTR 0011, XTR 0090 and
XTR 0091 with sensing head SE Ex LC M:
1)
The year of manufacturing is coded by the third capital letter of the serial number on the type plate:
U = 2004, W = 2005, X = 2006, Y = 2007, Z = 2008, A = 2009, B = 2010, C = 2011, etc.
Example: Serial number ARUL-0054, the 3rd capital letter is U, so the year of manufacturing is 2004.
Page 26 of 42
Typ XTR 0000, XTR 0001, XTR 0010 or XTR 0011
0158
II 2G EEx de IIC T6/T5/T4
II 2D IP 6x T85/T100/T135
C ≤ Ta ≤ +40/+55/+65
o
–40
TPS 04 ATEX 1 003 X
NON-INTRINSICALLY SAFE CIRCUITS
INTERNALLY IP30 PROTECTED
1)
Year of manufacturing
Dräger Safety, D-23560 Lübeck, Germany
Typ XTR 0090 or XTR 0091
0158
II 2G EEx de IIC T6
o
II 2D IP 6x T85
C
C ≤ Ta ≤ +65
o
o
–40
C
TPS 04 ATEX 1 003 X
NON-INTRINSICALLY SAFE CIRCUITS
INTERNALLY IP30 PROTECTED
1)
Year of manufacturing
Dräger Safety, D-23560 Lübeck, Germany
acc. to 89/336/EWG, acc. to EN 50 270
influence ≤5 % LEL (propane)
influence ≤0,5 % LEL (propane)
o
C
o
C
9023810 - 2nd edition - September 2005