Herunterladen Inhalt Inhalt Diese Seite drucken

SATA 244 Betriebsanleitung Seite 19

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

<< Operating instructions SATA filter 244/264/284 >>
sure is displayed on the pressure gauge [1-3].
4. Control pressure when operating the spray gun (trigger fully pulled)
and re-adjust, if necessary.
9.
Function
9.1. Filter stage [A]:
The first filter stage separates particles > 5 µm as well as condensed wa-
ter and oil. The sintered filter (Art. No. 22160) is integrated in the filter.
Notice!
Sintered filter:
• Fineness 5µm
• Surface 100 cm²
The automatic condensate drain valve [1-9] only works properly when the
filter is vertically mounted. If a certain condensate filling level is reached
inside the filter housing [1-12], the condensate drain valve opens auto-
matically draining the condensate through the condensate drain hose [1-
10] into the collection container (not included in delivery) until just a small
residual quantity remains.
9.2. Filter stage [B]:
The fine filter cartridge (Art. No. 81810) of the second filter stage sepa-
rates smallest particles.
Notice!
Fine filter cartridge:
• Special micro fibre fleece
• Fineness 0.01 µm, separation degree 99.998 % related to a particle
size > 0.1 µm
• Surface 300 cm²
9.3. Filter stage [C]:
Except for the installed filter cartridge, the design of the third filter stage is
identical to the second filter stage [B]. This third filter stage contains the
activated charcoal cartridge (Art. No. 85373). The activated charcoal
filter can only be used with the filter stages [A] and [B] preceding.
EN
III.5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

264284

Inhaltsverzeichnis