Invacare® HomeFill® II Oxygen System
DANGER!
Risk Of Death, Injury, Or Damage From Fire
Textiles, oil or petroleum substances, grease, greasy
substances and other combustibles are easily ignited
and burn with great intensity in oxygen enriched air and
when in contact with oxygen under pressure. To avoid
fire, death, injury or damage:
– DO NOT allow oil from your hands or other sources
to come into contact with the compressor coupling
or cylinder fittings. These substances may become
flammable in the presence of oxygen and cause injury.
Avoid touching the cylinder fitting whenever possible.
Example of items to avoid are hand creams or lotions,
cooking oils, suntan oils or sunblocks and similar oily
products. If you use these types of products Invacare
suggests you wash your hands prior to using the
HomeFill unit. If the cylinder fitting should come in
contact with such substances it should be cleaned
off with a damp cloth prior to connecting it to the
compressor.
– NEVER oil or lubricate the compressor coupler or
cylinder fittings. NEVER use any penetrating oil
or lubricant such as WD-40® or 3-in-1 Oil®. If
connection difficulty is experienced verify that the
cylinder fitting is being inserted straight down into
the compressor coupler. If continued difficulty is
experienced contact your supplier for assistance.
8
DANGER!
Risk of Electric Shock
This unit contains moving and high pressure components.
There are no user serviceable parts inside the cover. To
avoid electric shock, injury or death:
– DO NOT remove the cover.
– Refer servicing to qualified personnel.
WARNING!
Risk of Serious Injury or Damage
Use of non-Invacare accessories may result in serious
injury or damage.
– Invacare products are specifically designed and
manufactured for use in conjunction with Invacare
accessories. Accessories designed by other
manufacturers have not been tested by Invacare and
are not recommended for use with Invacare products.
– DO NOT use non-Invacare accessories.
– To obtain Invacare accessories, contact Invacare by
phone or at www.invacare.com
WARNING!
Risk of injury or damage
Blocking the air flow into and out of the compressor
may cause injury or damage.
– NEVER block the air openings of the product or place
it on a soft surface, such as a bed or couch, where the
air opening may be blocked.
– Keep the openings free from lint, hair and similar
foreign items.