Before all maintenance tasks on the
stapler always first disconnect it from
the air supply.
7.1 CLEANING THE STAPLER
This stapler does not require special servicing. It only
needs regular cleaning with a non-aggressive (non-
corrosive) cleaner agent. Do not remove any parts for
cleaning purposes!
Check the proper functioning of all safety
devices daily. Make especially sure that:
–
the trigger works smoothly, the door stays in place
and the magazine lid does not open itself.
–
all screws and nuts are securely tightened.
–
the stapler is regularly lubricated (refer to chapter
5.2).
7.2 REMOVING JAMMED STAPLES
To remove a jammed staple.
– Pry the door open with a screw driver (fig.5/1). It
is three notches in the door to simplified the disas-
semble.
– Remove the door..
– Clean the canal for defective staples.
– Insert the door into the rear nozzle plate and push
until it clicks shut.
Note! The three notches at the door must be as-
sembled to the front.