THE 'FUEL' INDICATOR
When the FUEL indicator appears, it means that there is only fuel left for 10
more minutes. The count-down of the remaining heating time can be seen in the
information display L (Fig. J). Now you have two options:
 you remove the fuel tank and refill it outside the living room (section B) or
 you push the button extension S. By pushing this button, the remaining
heating time will extend to 60 minutes.
The heater will automatically switch back to its lowest position. In the display
the number 60 will appear, which will decline to 10. At the arrival of 10,
you will hear an alarm signal every two minutes, warning you to refill the
removable tank. If you do not react, the heater will extinguish by itself. The
heater will also sound a warning signal, when it switches off. The fuel
indicator will blink, while four lines (--:--) are blinking in the information
display. You can stop this by pressing the
Once the heater has used up all its fuel and extinguished, it will take some time,
after the refill, before the heater is completely ready for use again.
K
THE 'VENT' INDICATO R
When there is insufficient ventilation in the room, an intermittent buzzer will
be heard (approximately once each 30 seconds) and the VENT indicator
be blinking. When this signal is given, ensure that the ventilation of the room
is improved (e.g. by opening a door or window a little more), to avoid that the
heater shuts off. When the ventilation of the room is improved, the VENT indicator
and buzzer will be deactivated. When there is still insufficient ventilation, the
heater shuts off automatically. When this occurs, e -1 1 is displayed and the
indicator is blinking and VENT indicator (
of the room (e.g. by opening a door or window a little more), the heater can be
ignited by pushing
L
MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance
work. Also disconnect the plug from the mains. Your heater needs hardly any
maintenance. It is, however, important that you clean the air filter 8 and the
vent filter 9 with a vacuum cleaner and the grid 2 with a damp cloth, both on a
weekly basis. Remove the air filter cap occasionally (Fig. L) and clean it with soapy
water. Prior to reinstallation, make sure that the air filter cap has fully dried.
Regularly inspect the fuel filter as well:
1 Remove the removable tank 7 from the heater and remove the fuel filter
(Fig. M). Some drops may leak from the filter; keep a cloth at hand.
2 Remove the dirt by tapping the fuel filter upside-down against a hard surface.
(never clean it with water!)
3 Reinstall the fuel filter into the heater.
We recommend that you remove dust and stains in time with a damp cloth,
because otherwise these may cause stains that are hard to remove.
!
Do not remove any heater components yourself. Always contact your dealer
for repairs. When the power cord is damaged, it may only be replaced by an
authorised fitter. Use a new cord of the type H05 VV-F.
button M once more.
) is lit. After improving the ventilation
M again.
J: When the FUEL
indicator has appeard,
the information display
will show the number of
minutes of fuel left in
the tank.
will
K: A blinking
indicator light is a sign
that you need extra
ventilation.
Fuel filter
4
9
L
M