Installation and Maintenance Guide
Technical data
6104, 6105
Working pressure:
Flow-rate at 300 kPa:
Hot water supply:
Noise class:
Protection class:
Electrical connection:
Max. power consumption:
Max. flow period:
Recognition range:
Afterflow period:
Pressure loss:
6134, 6135
Working pressure:
Flow-rate at 300 kPa:
Hot water supply:
Noise class:
Protection class:
Electrical connection:
Max. power consumption:
Max. flow period:
Recognition range:
Afterflow period:
General
The Electra Installation and Maintenance Guide introduces the operation,
installation, maintenance and use of the Oras Electra lavatory faucet. Please read the instructions
carefully prior to installation and save them for reference where servicing may be needed. If any fault or
malfunction occurs in the faucet, please seek the best possible advice at an expert HVAC store.
Function
Touchless Electra faucets are turned on and shut off by a solenoid valve that is actuated by a photocell.
When the hands are held under the faucet, the solenoid valve opens and water starts to flow. When the
hands are removed, the faucet shuts automatically.
Handshower
(see figure 1)
On models with handshower (6105 and 6135), water begins to flow from the spout when the showerhead
(18) is removed from its wall bracket (20).
If the button on the showerhead is pressed in, water begins to flow from the showerhead and water flow
from the spout stops.
Applications
Touchless Electra faucets are intended for use in areas that require a high standard of hygiene, e.g.
hospitals, doctors' offices, food processing plants etc. Electra faucets are also suitable for use where
there is a possibility that a faucet can be left running, e.g. public toilets, restaurants, schools etc.
The wash-basin to which the Electra faucet is to be fixed may not be of the kind that can be
plugged.
50 - 1000 kPa
0.11 l/s (with flow controller)
max. 80°C
I (ISO 3822)
IP 67
230 V
8 W
preset 2 min, range 1 - 255 s
preset, range 0 - 40 cm
preset 1 s, range 0 - 255 s
170 kPa at flow of 0.1 l/s
50 - 1000 kPa
0.11 l/s (with flow controller)
max. 80°C
I (ISO 3822)
IP 67 / transformer IP 40
230/12 V
15 W
preset 2 min, range 1 - 255 s
preset, range 0 - 40 cm
preset 1 s, range 0 - 255 s
11