3.2. Switch off of the Input-Impedance on the RGB-Inputs
With the switch A1 and A3 you can switch off the input-impedance of 750 Ω on the RGB-
video-input. You need this function if you use more than one monitor on the video-source.
Connecting several monitors to one single video signal, it is necessary to switch on the input
impedance at the last monitor in the row. ( all others are switched off)
switch
on/off
A1
ON
OFF
A3
ON
OFF
3.3. Monochrom Presentation
To switch of the signals R and B please use the switch A2. Only the green video-signal will
be presented. The presentation of the picture is performed only in green.
switch
on/off
A2
ON
OFF
3.4. Input-Impedance Sync-Signals
It is possible to switch the input impedance of the Sync-Signals H-Sync and V-Sync between
10 kΩ and 75Ω with switch A4. Standard-adjustment 10 Ω.
switch
on/off
A4
ON
OFF
3.5. Editing of Synchronization-Signals
Switch A5 is activating a function, which edits the synchronization-signals of „Sync On
Green". If you activate this function the input for horizontal and vertical sync-signals will be
switched off. The synchronization is performed through the green video-signal.
This function has to be activated if monitors with older controls- and visualization systems like
AS320, CP526, WF470, Teleperm-M, are in use. This function eliminates different bugs on
the synchronization-signals and passes on the prepared synchronization-signal to the visual
display unit. This editing function is for horizontal frequency 15 to 35 KHz.
switch
on/off
A5
ON
OFF
1815
LCD-Monitor SCD
function
input impedance red, green 75 Ohm
input impedance red, green 10 KOhm
input impedance blue 75 Ohm
input impedance blue 10 KOhm
function
Monochrome presentation (switch off red, blue)
Colour presentation ( red, green, blue active)
function
75Ω
10kΩ
function
Sync-editing function activate
Sync-editing function deactivate
-I
page 38 / 60
Operating Instruction
DOC-No.: B30056DE6.doc