P74344ea_F1DW116-216C_QIG
2
Step 1: Remove the contents from the box.
Step 2: Install the rack-mount brackets and place the Switch on a rack.
Step 3: Decide whether the Switch will be used in a single-unit configuration
or in a daisy-chained configuration. If the unit will be used in a
daisy-chained configuration, skip to Step 1 of "Daisy-Chain
Configuration". Otherwise, proceed to Step 4.
Step 4: Attach the IEC power cable to the power connector located on the rear
of the Switch.
Step 5: Using an RJ45 CAT5 or CAT6 cable, connect to a free port on your
KVM Switch.
Initial switch position for video compensation
Length of
CATX cable
0-200 ft.
100-300 ft.
200-400 ft.
300-500 ft.
400-600 ft.
500-700 ft.
600-800 ft.
700-900 ft.
800-1000 ft.
17-10-2003
Installation
Low resolution
640x480 to 1024x768
Position 0
Position 1
Position 2
Position 3
Position 4
Position 5
Position 6
Position 6
Position 7
16:51
Page 4
Medium resolution
800x600 to 1600x1200
Position 0
Position 1
Position 4
Position 5
Position 6
Position 6
Position 6
Position 6
Position 7
High resolution
1024x1280 to 2048x1536
Position 0
Position 2
Position 5
Position 6
Position 7
Position 7
Position 7
Position 7
Position 7