9.4
MAINTENANCE
at a specialised assistance centre.
Clean the tube bundle using a metallic brush or scrap off
the combustion residues using a suitable tool.
You also have to clean the smoke loop at the top of the
stove:
demount the stove top removing the two screws
that connect the two upper elements and remove
the front side of the cover (- 9.2 -)
demount the two elements of the smoke loop (points
Please clean the emissions reduction system at least
carefully remove it from its housing
clean the active element blowing air between the
smoke passage holes.
inside the combustion chamber, at its top. Remove them
and clean them at least twice a season. To remove them
from their housing you just have to slightly lift and bend
them (- 9.4 -).
sure that you restore the removed objects to their original
position.
to connect with one another, without leaving any gap
between them.
9.5
CLEANING THE FLUE PIPE
be carried out before the period the stove will be used
and any time you notice a build-up of soot and tar, which
Incrustations, once they reach a thickness of 5-6 mm,
in the presence of high temperatures and sparks may
.
In normal operating conditions, the chimney must be
cleaned after every 4 tonnes of wood burnt, or at least
once a year, unless otherwise required by regulations.
INSTALLATION
3
1
2
- 9.2 -
- 9.3 -
- 9.4 -