1. DESCRIPTION.

Electronic timer-thermostat for ON/OFF ambient temperature con-
trol (heating and air-conditioning), daily/weekly programming, class I
temperature control device (contribution 1%) - 3 modules .
• 16575: supply voltage 120-230 V~ 50-60 Hz, 6(2) A 230 V~
change-over relay output .
• 16576: supply voltage 3 V d .c . with 2 AA LR6 1 .5 batteries (not
included) 5(2) A 250 V~ change-over relay output .

2. SCOPE.

The chronothermostat is suitable for ambient temperature control by
regulating the supply circuit of the burner or heat pump (heating), or
the supply circuit of the air conditioner (air conditioning), to maintain
ideal temperature conditions seven days a week . Its multiple func-
tions enable the user to choose between the fixed programs stored
in memory, or to create personalised programs .
The roomy display shows the ambient temperature, the day of the
week, the time, the status of the heating or air conditioning system
and the daily temperature profile for the currently active program .
There is a simple and intuitive procedure for programming all the
parameters, assisted by interactive menus (all instructions shown on
the display), using the 4 buttons on the front of the chronothermo-
stat .
18 - ENGLISH

3. INSTALLATION.

The thermostat must be installed in flush or surface mounting boxes
with mounting frames and cover plates at a height of 1,5 m above
floor level, in an appropriate position for measuring the ambient tem-
perature; do not position the instrument inside niches, behind doors
and curtains, close to heat sources or in areas influenced by outside
weather conditions . In particular, it should not be installed on pe-
rimeter walls or near electrical devices which generate heat (e.g.
dimmers or lamps).
The thermostat is designed for use in dry, dust-free areas with an
ambient temperature between 0 °C and +40 °C .