Cleaning the Condenser
Periodically cleaning the condenser can extend the life of the appliance.
Note: Use a soft brush or vacuum cleaner to clean the fins of the condenser,
taking care not to damage the fins.
Troubleshooting
If your appliance develops a fault, please check the following table before making a call to the Helpline.
Fault
The appliance is not
working
The appliance turns on,
but the temperature is
too high/low
The appliance is
unusually loud
CS102-CS103_GL186-GL189-GL455-GL457_ML_A5_v4_171213.indb 5
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Condenser blocked with dust
Doors/ drawers are not shut
properly
Appliance is located near a
heat source or air flow to the
condenser is being interrupted
Ambient temperature is too high
Insufficient airflow to the fans
Appliance is overloaded
Factory default parameters
adjusted
The appliance is touching a
neighbouring object
The appliance has not been
installed in a level or stable
position
Solution
Check the unit is plugged in correctly and
switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Clean Condenser
Check doors / drawers are shut and seals
are not damaged
Move the appliance to a more suitable
location
Increase ventilation or move appliance to a
cooler position
Remove any blockages to the fans
Reduce the amount stored in the appliance
Call POLAR agent or qualified Technician
Check installation position and change if
necessary
Check installation position and change if
necessary
UK
5
2017/12/13 10:33