WARNING CODE
E 0 0 1
E 0 0 2
E 0 0 4
E 1 0 1
E 1 0 4
E 1 0 5
E 1 0 6
E 1 0 7
E 1 0 8
E 1 0 9
E 1 1 0
E 1 1 1
A 0 0 2
A 0 0 6
A 0 0 7
32
DESCRIPTION
Faulty control panel
Remote control signal communication error
Communication error
Outlet water temperature too high
Failed ignition error
Brazier cleaning system jammed
Temperature probe malfunction
Temperature probe malfunction
Combustion chamber probe malfunction
Thermal cutout error
Pressure error or air control error
Temperature probe malfunction
Flue gas temperature probe malfunction
Scheduled maintenance warning (icons
Warning - door or drawer open
Pressure sensor malfunction
Clean stove
Failed ignition error
;
shows the error code on the display:
POSSIBLE CAUSES
Control panel fault
Control panel fault
Connection cable between board and control panel
interrupted or detached.
the error
No pellets
Faulty ignition system
Burn pot dirty
Problems with the heating system
Problems with the pump
A foreign body is stopping the brazier cleaning
system from operating.
Faulty return water temperature probe
Faulty combustion chamber probe
Problems with the heating system
Problems with the pump
Problems with overheating in the pellet hopper
Flue system dirty
Seals worn
Combustion air control system fault
Faulty outlet water temperature probe
Pressure sensor or board fault.
system dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
No pellets; Faulty ignition heater; Worn gaskets;
LED