RF200 System planen
4.2 Felddaten von Transpondern und Readern
Tabelle 4- 10 Felddaten SIMATIC RF260R
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D423
MDS D424
MDS D426
MDS D428
MDS D460
Alle Angaben in mm.
Tabelle 4- 11 Felddaten SIMATIC RF290R, mit ANT D5
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D424
MDS D426
MDS D460
Alle Angaben in mm.
38
Länge des Übertragungs-
fensters (L)
120
80
110
120
60
120
120
80
80
110
140
55
80
75
50
50
Länge des Übertragungs-
fensters (L)
320
300
320
320
300
320
320
320
300
320
320
300
320
300
Arbeitsabstand (S
)
a
2 ... 110
2 ... 80
2 ... 75
2 ... 80
2 ... 40
2 ... 120
2 ... 100
2 ... 75
2 ... 60
2 ... 65
2 ... 110
2 ... 40
2 ... 60
2 ... 70
2 ... 40
2 ... 40
Arbeitsabstand (S
)
a
0 ... 400
0 ... 200
0 ... 350
0 ... 400
0 ... 130
0 ... 350
0 ... 400
0 ... 300
0 ... 200
0 ... 300
0 ... 400
0 ... 200
0 ... 300
0 ... 120
Systemhandbuch, 09/2013, J31069-D0227-U001-A8-0018
Grenzabstand (S
)
g
130
85
100
110
45
135
120
90
70
80
140
45
70
85
45
45
Grenzabstand (S
)
g
500
280
400
500
180
450
500
400
280
380
500
280
350
160
SIMATIC RF200