ENGLISH
 Please use the original packing when the device is to be transported.
 Due to safety reasons it is prohibited to make unauthorized modifications to the unit.
Important: Never look directly into the light source! Don't use the effect in the presence of persons suffering
from epilepsy.
DESCRIPTION:
1. Front with hard plastic cover to protect the
5mm LEDs.
2. Hanging bracket with knobs on both sides to
fasten the unit and a mounting hole to fix a
mounting hook.
3. ¼" jack used to connect the optional CA-8
controller
4. Mains input with IEC socket and integrated
fuse holder, connect the supplied mains cable
here.
5. Mains output with IEC socket: you can use a
special IEC power cable to connect this output
with the mains input of the next PLANO SPOT
for easier linking. (max 40 units can be linked)
6. DMX-output connector
7. DMX-input connector
8. Slave LED: is lit when the unit is in slave
mode
9. Sound LED: blinks to the rhythm of the music
while the unit is in audio mode
10. DMX LED: is lit when the unit receives a
DMX-signal
11. Master LED: is lit when the unit is switched as
master
12. MENU button: used to select the different
menu items
13. DOWN button: to go back in the menu and to lower the values shown on the display.
14. UP button: to go up in the menu and to increase the values shown on the display.
15. ENTER button: used to confirm your choice.
16. DISPLAY shows the various menus and the selected functions.

ELECTRICAL INSTALLATION

Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Electrical installation for 1 standalone unit:
 Insert the mains cable. The unit starts working immediately in the last selected stand-alone mode.
 Refer to chapter HOW TO SETUP to learn how to switch between static and sound mode.
Remark: You can connect a CA-8 remote controller to the unit if you want to have more control.
Electrical installation for two or more units in master/slave:
 Connect 2 to maximum 16 units together using good quality balanced microphone cables. The unit that
has no cable connected to its DMX-input is the "master", the others are the slave units.
 Make sure that all units are connected to the mains.
 Refer to chapter HOW TO SETUP for more information.
 Done!
Remark: You can connect a CA-8 remote controller to the master unit if you want to have more control
over the master/slave operation. You can also connect the LEDCON 02 remote controller