Herunterladen Inhalt Inhalt Diese Seite drucken

Lamp Replacement; Installation; Maintenance; Specifications - JB Systems Light PUBLI SPOT Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
ENGLISH
EXCHANGE GOBO
1. Remove steel ring from the front side and take out the gobo.
2. Place the new gobo and fasten with the steel ring.
LAMP (RE)PLACEMENT
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.
Always unplug the unit before servicing! Always use the same type of
spare parts (bulbs, fuses, etc.) When replacing parts, please use only
genuine spare parts.
 Switch off the unit and unplug the mains cable.
 Wait for about 15 minutes until the unit has been cooled down.
 Loosen the 2 screws that close the lamp compartment of the fixture. (see picture)
 Gently pull out the cover containing the GU-10 lamp socket.
 Remove the old lamp by turning it ¼ turn counterclockwise out of the socket.
Attention! Check the label on the device or see the technical specifications in this manual to know which
lamp should be used. Never install lamps with a higher wattage! Lamps with higher wattage generate
temperatures the device was not designed for. If the device uses a lamp transformer, it will burn due to
current overload.
 Place the new lamp in the socket and turn it ¼ turn clockwise.
 Don't touch the cover glass of the lamp with bare hands! This
drastically shortens the lifespan of the lamp. If you touched the
cover glass, clean it with a cloth and a little denatured alcohol.
Wipe the lamp off before installing.
 Close the lamp compartment and fasten both screws.
 Done!

INSTALLATION

Important: The units' surface temperature may reach up to 90°C!
Always install this projector in an area where people can NOT TOUCH it, even accidentally.
Touching the hot projector can cause serious injuries.
 Make sure the area below the installation place is free from unwanted persons during installation and
servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before installation make sure that the installation area can hold a minimum load of 10times the device's
weight.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result in overheating.
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
JB SYSTEMS
®
OPERATION MANUAL
3/26
PUBLI SPOT
ENGLISH
OPERATING INSTRUCTIONS
 Once connected to the mains, switch it on with the switch located on the mains cable: the device starts
running.
 Do not switch the unit on and off in short time intervals as this reduces the lamp life.
 The units' surface temperature may reach up to 90°C. Don't touch the housing with bare-hands during its
operation.
 Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.
 In the event of serious operating problems, stop using the fixture and contact your dealer immediately.
 Important: Never look directly into the light source!

MAINTENANCE

 Make sure the area below the installation place is free from unwanted persons during servicing.
 Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
 Clean the optics at least once every 30 days.

SPECIFICATIONS

Mains Input:
AC 230V, 50Hz
Power consumption:
43 Watt
Gobo diameter:
37,8mm (image diameter = 20mm)
Lamp:
HID 32/12°
Dimensions:
284.1 x 95.0 x 165.0mm
Weight:
1,2kg
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
JB SYSTEMS
®
OPERATION MANUAL
4/26
PUBLI SPOT

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis