02. Keep the n key pressed again and wait for the motor to perform 4 movements. Upon completion, release the key.
03. Keep the t key pressed and wait for the motor to perform 2 movements. Upon completion, release the key.
04. Adjustment of the position: Keep the t (or s) key pressed until the awning reaches the desired "1" height. Note – to adjust the height with precision, press
the s and t keys several times consecutively (at each pulse the awning moves a few millimetres).
05. Keep the n key pressed and wait for the motor to perform 3 movements. Upon completion, release the key. WARNING! – If the motor makes 6 move-
ments, you must perform the procedure 5.6.1. Upon completion, repeat the procedure 5.6.3.
01
5
sec.
04
Notes • When performing the procedure, at any time you can cancel it by keeping the n and t keys pressed simultaneously for 4 seconds. Otherwise, do not press
any key and wait 60 seconds for the motor to perform 6 movements. • After the adjustments, the s key will command the Raising motion and the key t key will
command the Lowering motion. The awning will move within the limits constituted by the two limit switch heights.
5.7 - Semiautomatic programming of the limit switches
WARNING! – This programming applies to awnings which have the box, thus with retainer in the Upper limit switch "0". The
same procedure also applies when the retainer is in the Lower limit switch "1".
Warnings • The first limit switch to be adjusted must be the one with the retainer against the structure: the procedure below is an example of programming
for an awning with a box. • This procedure overwrites previously adjusted heights with the new heights using this same procedure. • Memorising the limit switches with
this procedure, the two heights are controlled and updated constantly by the "limit switch self-update" function (see paragraph 7.2). • Every time the motor is powered,
2 movements are performed if at least one transmitter and the limit switch heights are not in the memory.
Before starting the procedure, bring the awning to the midpoint of its stroke.
01. Run the UP command by keeping the s (or t) key pressed and wait for the awning to stop automatically as result of the impact against the structure (= upper
limit switch "0"). Upon completion, release the key.
02. Run the Down command by keeping the s (or t) key pressed and release the key when the awning is next to your chosen lower limit switch "1".
03. Keep the n key pressed and wait for the motor to perform 2 movements. Upon completion, release the key.
04. Keep the n key pressed again and wait for the motor to perform 4 movements. Upon completion, release the key.
05. Keep the t key pressed and wait for the motor to perform 2 movements. Upon completion, release the key.
06. Fine adjustment of position: Press the t and s keys until the awning reaches the "1" height you want (at each pulse the awning moves a few millimetres).
07. Keep the n key pressed and wait for the motor to perform 3 movements. Upon completion, release the key.
01
03
2
5
sec.
06
fine adjustment
Notes – When performing the procedure, at any time you can cancel it by keeping the n and t keys pressed simultaneously for 4 seconds. Otherwise, do not press
any key and wait 60 seconds for the motor to perform 6 movements. • After this programming, the s key will command the Raise manoeuvre and the t key will com-
mand the Lower manoeuvre. During the Raising manoeuvre, the awning will be stopped by the impact against the mechanical blocks of the structure (= upper limit
switch "0"), while during the Lowering manoeuvre the awning will stop at the lower limit switch ("1") estabilished by the installer.
02
2
sec.
"1"
limit switch "1" desired
"0"
04
5
sec.
07
"1"
5
sec.
03
4
5
05
"1"
fine adjustment
02
4
3
2
5
sec.
3
5
sec.
05
2
5
sec.
"1"