Installation of the carbon filter
Remove the grease filters
The charcoal filters are located at both end of the motor. Turn the charcoal filters until they are unscrewed.
The carbon filters should be replaced every 3 - 6 months or if they show signs of damage.
Fault
Light on, but fan does not work
Both light and fan do not work
Serious Vibration of the unit
Suction performance not good

Troubleshooting

Cause
The fan blade is jammed.
The motor is damaged.
Light bulb burn
Power cord looses.
The fan blade is damaged.
The fan motor is not fixed tightly.
The unit is not hung properly on the
bracket.
Too long distance between the unit
and the cooking plane.
Solution
Switch of the unit and repair by quali-
fied service personnel only.
Replace the bulb with correct rating.
Plug in to the power supply again.
Switch of the unit and repair by quali-
fied service personnel only.
Switch of the unit and repair by quali-
fied service personnel only.
Take down the unit and check whether
the bracket is in proper location.
Readjust the distance to 65-75 cm.