Compressor mounting brackets removal
For packaging and transporting the compressor is fi xed to the frame by special brackets which must be removed before oper-
ating the machine.
• loosen and remove the two screws V attached posteriorly to the frame;
• remove the front bracket S1;
• remove the bracket S2 positioned behind the compressor.
S
Store the brackets and screws so you can reuse them if you need to move the dehumidifi er.
M1100-0_draft-0