RH4xxLD, RH4xxLG
Control element
No. in
Description
fig. 1, page 3
1
Temperature controller
Defrosting function
Frost will gradually form on the cooling surfaces. To prevent this frost-formation the
appliance has a function switching off the cooling unit for two hours in every
24 hours.
During the two hour defrosting phase the frost will melt and the defrost water runs
into an evaporating vessel located at the bottom rear of the refrigerator. The defrost
water evaporates automatically so that the vessel does not have to be emptied man-
ually.
6
Installation
The cooling device is designed for free-standing installation, but it can also be
installed in a built-in cabinet. To ensure satisfactory operation and maximum cooling
efficiency the following installation conditions have to be fulfilled.
•
The cooling device must be levelled carefully to ensure proper function.
•
The clearance between the cooling device's back and the wall should be 20 mm
or more.
Ventilation must be provided as shown in alternatives A, B, C or D (fig. 2,
•
page 3).
•
The ventilation duct must at least measure 105 mm x the width of the cooling
device.
The entire cooling unit must project into the ventilation duct as shown (fig. 2,
•
page 3). Other parts of the device may not project into the ventilation duct.
•
Air passing through the ventilation duct must not be preheated by any source of
heat.
•
Ventilation grills, if used, must have openings of at least 200 cm².
•
Moisture will condense on the door of the glass door version, when the ambient
humidity is above 65 % in 25 °C ambient temperature.
•
The cooling device can be fixed to furniture by inserting screws of an appropriate
length through the device feet (fig. 3, page 3).
•
The socket outlet for the mains connection must be freely accessible.