This transportation cap
is packed separately in
the box. Only this cap
ensures trouble-free
transportation of the
heater after use.
Store it well!
B
C
D
E
F
Using the right fuel is therefore essential for safe, efficient, and comfortable use
of your heater.
Damage and/or malfunctions of the heater due to the use of other than high qua-
lity water-free pure paraffin oil is not covered by the warranty.
Always refer to your local dealer for the right fuel for your heater.
MANUAL
A

INSTALLING THE HEATER

1
Carefully remove your heater from the box and check the contents.
In addition to the heater you also need to have:
a transportation cap
these directions for use
a manual fuel syphon pump
Keep the box and the packaging materials (Fig. A) for storage and/or
transportation.
2
Remove the other packaging materials:
emove the packaging material from the grill ¶. Lift the grill from the slot
(Fig. B) and pull it forward.
Pull both ends of the packaging to the rear and at the same time slightly
downwards (see Fig. C).
Remove the combustion chamber from the heater and remove the pac-
kaging underneath (see Fig. D).
Put the combustion chamber back into its place. The combustion chamber
is positioned correctly when it can be smoothly moved a little to the left
and to the right by its handle ´ (Fig. E). Close the grill: Slightly lift it to
reposition it in its slot.
Open the lid of the removable tank º and remove the piece of cardboard.
3
Fill the removable tank as indicated in Section B.
4
Insert the batteries into their holder ¹ at the back of the heater (Fig. F).
Ensure that the positive and negative poles match the + and - marks indica-
ted on the battery housing.
A
4