- EN -
Maintenance and cleaning
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
Cleaning the device
Clean the unit with a soft, clean and dry cloth. Never use aggressive cleaning agents or chemical solutions. These can
attach the housing surface or impair the function.
Replacing the fuse (only InScenio FM-Master 3)
The dimmer is protected by a fine-wire fuse.
Please contact your specialist dealer if you do not wish to undertake the replacement yourself.
How to replace the fuse:
• Pull the plugs of all units connected to power supply distributors.
• Isolate the power supply distributor.
• Hold the unit, then turn the fuse holder counter-clockwise by a quarter of a turn using a screw driver and exerting light
pressure (bayonet closure).
• Remove the fuse holder including fuse.
• Replace the fuse.
Use fine fuse 5 × 20 mm, 2 A slow-blow.
• Turn in the fuse holder again.
• Reconnect the unit.
Changing the battery
How to replace the battery in the manual transmitter:
• At the manual transmitter (G, 4) push back the bottom section of the cover (13).
• Replace battery (14).
Use alkaline-manganese battery, type V23 GA (12 V).
• Close cover.
• Dispose of batteries in an environmentally friendly manner.
Spare parts
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
14
www.oase-livingwater.com/spareparts