Herunterladen Inhalt Inhalt Diese Seite drucken

Amprobe IR-710 Bedienungshandbuch Seite 129

Vorschau ausblenden Andere Handbücher für IR-710:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 165
Trigger Lock
The thermometer trigger can be locked on for continuous measurement.
To lock the trigger:
1. Press SET button to select Trigger Lock set-up, icon
2. Press
or
to select ON or OFF.
3. Press YELLOW button to complete the setting and exit Trigger Lock set-up, or press SET button to complete the
setting and continue setting for °C / °F.
°C / °F Set-up
1. Press SET button to select °C / °F set-up, icon °C or °F is blinking on the display
2. Press
or
to select °C or °F.
3. Press YELLOW button to complete the setting and exit °C / °F set-up.
MAX, MIN, DIF, AVG
The thermometer can measure maximum (MAX), minimum (MIN), differential (DIF) or average (AVG)
temperatures each time a reading is taken. These values are available for infrared measurements.
1. Press YELLOW button until MIN or MAX or AVG or DIF appears on the display
2. Pull and hold the trigger while aiming at the target surface.
3. The value will show on secondary display.
High Alarm (HAL) and Low Alarm (LAL)
The thermometer has a programmable high and low alarm to designate high or low readings depending on
the thresholds entered. When the alarm level is reached, an alarm will sound. This feature is not available when
measuring by thermocouple.
To set either the high or low alarm:
1. Press YELLOW button to select HAL or LAL option.
2. Press
or
to adjust the threshold value.
3. Press SET button to complete the setting. Symbol
To turn off the high or low alarm:
1. Press YELLOW button to select HAL or LAL option.
2. Press SET button. Disappearance of Symbol
DATA Memory
The thermometer has 99 points data storage and the stored data can be downloaded via IR-750 /
IR-750-EUR software. To save the data:
1. Press YELLOW button to select DATA option.
2. Press
or
to select data record number
3. Pull and hold the trigger while aiming at the target surface, press DATA button to save the measurement value.
You can also save the measurement value within 8 seconds of display hold after releasing the trigger.
K-Type Thermocouple Measurement
X�
To avoid electrical shock or personal injury, do not connect the thermocouple contact probe to live
electrical circuits.
The thermometer comes with a bead K-type thermocouple probe.
K-type thermocouple is connected to the thermometer via TC-K input connector located on right side of
the thermometer. The probe can be used simultaneously while the thermometer is taking non-contact
measurements.
1. Press YELLOW button to enter T-C mode. The display shows OL before the measurement is made.
2. Connect the K-type thermocouple to the thermometer via TC-K input connector located on right side of
the thermometer. Press the trigger to start measuring. Secondary display shows the measurement reading.
3. Release the trigger, the reading is kept on display (display hold: 8 seconds)
is blinking on the display
or
will appear on the display.
or
on the display indicates high or low alarm is off.
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis