Dimensions (see page 9) Recommended hot water temp.: 65°C Centre distance: 150 ±12 mm Flow diagram Connections G 1/2: cold right - hot left (see page 9) Thermal disinfection: max. 70°C / 4 min Spare parts (see page 10) • Anti-pollution function • Hansgrohe mixers can be used together with hydrauli- Cleaning cally and thermically controlled continuous flow heat- see enclosed brochure. ers if the flow pressure is at least 0,15 MPa. • The product is exclusively designed for drinking water! Fault Cause Remedy - Shower filter seal dirty - Clean filter seal between shower Insufficient water and hose - Non return valve hasn‘t moved back - Exchange non return valves - Cartridge defective, calcified...
Seite 3
(1 MPa = 10 bar = 147 PSI) Heißwassertemperatur: max. 80°C Durchflussdiagramm Empfohlene Heißwassertemperatur: 65°C (siehe Seite 9) Anschlussmaße: 150 ±12 mm Anschlüsse G 1/2: kalt rechts - warm links Serviceteile (siehe Seite 10) Thermische Desinfektion: max. 70°C / 4 min Reinigung • Eigensicher gegen Rückfließen siehe beiliegende Broschüre. • Hansgrohe Armaturen können in Verbindung mit hydraulisch und thermisch gesteuerten Durchlauf- erhitzern eingesetzt werden, wenn der Fließdruck mindestens 0,15 MPa beträgt. • Das Produkt ist ausschließlich für Trinkwasser konzi- piert! Störung Ursache Abhilfe - Siebdichtung der Brause ver- - Siebdichtung zwischen Brause und Wenig Wasser schmutzt Schlauch reinigen - Rückflussverhinderer sitzt fest - Rückflussverhinderer austauschen - Kartusche defekt, verkalkt - Kartusche austauschen Armatur schwergängig...
Seite 4
Silicone min. max. 34 mm 39 mm max. 5 mm...
Seite 5
SW 30 mm 17 Nm SW 22 mm > 2 min SW 22 mm (2 Nm)