An external shutter that is not
installed correctly may result in non-
intended operation or impermissible
operation. Operation is only permissible with
a correct installation position (Maico logo at
bottom right).
Risk of injury in entrance areas if ice
forms due to falling icicles. Never
install external shutter above entrance areas
that are not covered.
Risk of injury and health risk in the
event of changes or modifications or
if components which are not permitted are
used. The unit may only be operated with
original components. Changes and
modifications are not permitted and release
the manufacturer from any guarantee
obligations and liability, e.g. if the unit is
drilled at a point which is not permitted.
Danger of injury when working at
heights. Use appropriate climbing aids
(ladders). Stability should be ensured, if
necessary have the ladders steadied by a
2nd person. Ensure that you are standing
securely and cannot lose your balance and
that there is no one under the unit.
Depending on type, sound power
levels of up to 66 dB(A). When
planning, take into account sound insulation
at the installation site when planning.
Risk of death from carbon monoxide
when operating with air-ventilated
fireplaces. Ensure sufficient supply air intake
during operation with an air-ventilated
fireplace. The maximum permitted pressure
difference per living unit is 4 Pa. The consent
of a professional chimney sweep is needed in
all cases.
4. Safety instructions and warnings │ UK
Danger of electric shock when
operating with damaged external
shutter. Do not dismantle external shutter.
Only operate the external shutter when it is
completely installed. Do not commission a
damaged unit.
Danger if the relevant regulations for
electrical installations are not
observed.
Before installing the electrics, shut down all
supply circuits, deactivate the mains fuse and
secure it so it cannot be switched back on.
Attach a warning sign in a clearly visible place.
Be sure to observe the relevant regulations
for electrical installation; e.g. EN 50110-1, in
Germany this is particularly VDE 0100,
with the corresponding parts.
A mains isolation device with contact
openings of at least 3 mm at each pole is
mandatory.
Only connect unit to a permanently wired
electrical installation with NYM-O / NYM-J,
3 x 1.5 mm² or 5x 1.5 mm² (depending on unit
type) cables.
The units may only be operated using the
voltage and frequency shown on the rating
plate.
The degree of protection stated on the
rating plate is only guaranteed if installation
is undertaken correctly and the connection
cable is attached correctly.
Unit may be energized even when at a
standstill and may be switched on
automatically by sensors, such as for time
delay or humidity etc. Maintenance and fault
finding only permissible when carried out by
trained specialists.
Exercise caution when handling
packaging materials. Observe
applicable safety and accident prevention
requirements. Store packaging material out
of the reach of children (risk of suffocation).
9