4
Electrical installation
Important notes
4
Electrical installation
4.1
Important notes
Installation must
ƒ
–
always be in accordance with the operating conditions specified in the
Technical data (¶ 24).
–
be carried out to EN 60204−1.
Please observe the following when selecting the cable type:
ƒ
–
The cables used must comply with the approvals required for the
application (e. g. VDE, UL etc.).
–
Fuses and cable cross−sections must be dimensioned in accordance with
the specifications in the documentation for the basic device.
{
Danger!
Dangerous voltage
All power connections carry dangerous voltages both if the motor is
at standstill and after up to 3 minutes after mains switch off.
Possible consequences:
ƒ
Protective measures:
ƒ
ƒ
28
Death or severe injuries after touching the power connections.
Wait for at least 3 minutes before working on the power
connections.
Check whether all power connections are de−energised.
l
EDKZS3−480A200 DE/EN/FR/ES/IT 1.0