Maximum operating pressure
Maximum operating temperature
5
Preparations at the workplace
5.1
Assembling water supply unit
1. Check whether the tank, pump and hose are undamaged before assembly.
2. Connect the hose on the drain opening [1].
3. Pump up the empty water supply unit to 2 bar [2].
◁ The pressure must not drop by more than 0.5 bar within 30 minutes!
4. Pull the red button of the safety valve for checking [3].
◁ The pressure must be released.
5.2
Fill water supply unit
1. Fill the water into the tank [1].
2. Check the fill level on the hose [2].
3. Route the transparent hose several times on the tank from top to bottom [3].
◁ The liquid level in the hose and tank are equalized. The liquid level visible in the hose then matches
the filling level in the tank, which you can read off on the scale.
5.3
Preparing water supply unit
1. Screw the pump into the tank [1].
2. Press the pump handle downward and turn it clockwise [2].
◁ The pump handle has been released.
3. Generate a pressure of approx. 2 bar in the tank [3].
◁ The maximum pressure should not exceed 6 bar (red line on the pressure gage). If the maximum
pressure is exceeded, the safety valve is actuated and releases the excess pressure.
4. Press the pump handle downward and turn it counterclockwise.
◁ The pump handle is locked.
6
Use
5
1. Connect the plug-in connector of the water pressure tank with the plug-in nipple [1].
2. Actuate the ball valve.
◁ The liquid supply begins.
◁ The liquid quantity can be regulated with the ball valve.
3. Continue pumping if the pressure drops below 1 bar [2].
4. When the tank is empty, refill it.
7

After use

6
1. Pull up the red button of the safety valve until the tank is completely depressurized.
2. Close the ball valve and disconnect the plug-in connection and plug-in nipple [1].
3. Lock the pump handle.
4. Screw the pump out of the tank.
5. Drain the remaining water from the tank.
6. Wipe off the water supply unit with a damp cloth.
7. Coil the hose around the tank and mount the plug-in connection on the locating pin of the water supply
unit [2].
8. Keep the water supply unit in a dry, frost-free environment protected from direct sunlight for drying and
storage.
247636