will sound all connected alarms, however will not
enable the relay to switch its contacts.
It is advised that alarms are tested in accordance with
the respective instruction manuals.
Frequent testing of the relays is advised to ensure its
continued and safe operation.
Guidelines and best practices for testing are as follows:
1. After the system is installed.
2. After prolonged absence from the dwelling (e.g. after
holiday period).
3. After repair or servicing of any of the system's
elements or household electrical works.
ALARM
In the event of an alarm (from a local network or from an
external source) the local network will sound a full alarm
and the red LED on the relay will activate continuously.
Smoke / heat and CO alarms, properly installed and
maintained, are an essential part of a good home
safety programme. Please refer to individual alarm
manuals for more information.
TROUBLESHOOTING
The relay unit Power
LED is not illuminated
on the Relay Unit.
The green LED flashes
every 60 seconds.
The red LED flashes
and a buzzer sounds
every 60 seconds.
The red LED is
continuously showing.
14
Check that the battery
back-up switch is
on. The green unit
power LED should be
illuminated.
There is no mains power
to the relay unit. It is
powered by the battery.
The battery back-up is
low and the relay unit
needs replacing.
The network is in alarm.
Respond immediately.