Puissance frigorifique nominale
Nominal cooling capacity
Kälteleistung, nominal
Liquide
Liquid
Raccordements
Flüssigkeit
Connections
Aspiration
Anschlüsse
Suction
Sauggas
Modèle
Model
Modell
Type
Type
Typ
Compresseur
Tension
Compressor
Supply
Verdichter
Spannung
Id
Imax
Nbre x diamètre
No. x diameter
Anz. x Durchmesser
Débit d'air
Air flow
Luftvolumenstrom
Ventilateur
Fan
Tension
Ventilator
Supply
Spannung
Puissance utile
Useful power
Leistung
Imax
Volume réservoir
Receiver volume
Sammlervolumen
DESP 97/23/CE Cat. Risque
PED 97/23/EC Risk Cat.
DGRL 97/23/EG Risikokategorie
Niveau sonore
Sound level
Schalldruckpegel
Fig.
Longueur
Lenght
Länge
Dimensions
Largeur
Dimensions
Width
Abmessungen
Breite
Hauteur
Height
Höhe
Poids
Weight
Gewicht
Modèle
Model
Modell
Nbre x diamètre
No. x diameter
Anz. x Durchmesser
Débit d'air
Air flow
Luftvolumenstrom
Ventilateur
Fan
Tension
Ventilator
Supply
Spannung
Puissance utile
Useful power
Leistung
Imax
Dégivrage électrique
Electrical defrost
Elektroabtauung
Longueur
Lenght
Länge
Dimensions
Largeur
Dimensions
Width
Abmessungen
Breite
Hauteur
Height
Höhe
Poids
Weight
Gewicht
(1) Conditions nominales au R404A :
Température de chambre -25°C.
Température extérieure +32°C.
(2) Intensité de démarrage (courant rotor bloqué) du compresseur.
(3) Intensité max. de fonctionnement.
(4) Les niveaux de pression acoustique (en dBA à 10 mètres) sont indiqués en
champ libre.
Le fonctionnement à un régime différent de ces conditions nominales peut
conduire à des résultats différents.
Les résultats obtenus sur le lieu de l'installation peuvent être différents
par rapport aux valeurs du catalogue, du fait de phénomènes de réflexion
(présence de mur, etc ...).
L'affaiblissement du niveau sonore en fonction de la distance est théorique et
les phénomènes de réflexion et de résonnance peuvent modifier le résultat, soit
au niveau global pondéré, soit sur certaines fréquences.
8
LOW TEMPERATURE APPLICATION
ZF09 Z
ZF11 Z
(1)
kW
2,27
2,68
inch
3/8"
3/8"
inch
7/8"
7/8"
GSS
GSS
ZF09 Z
ZF11 Z
ZF09K4E
ZF11K4E
TFD
TFD
(2)
A
40
46
(3)
A
6,0
7,0
mm
1xØ450
1xØ450
m³/h
4900
4900
W
260
260
(3)
A
1,25
1,25
dm³
4
4
I
I
(4) dB(A)
49
50
1
1
mm
1047
1047
mm
785
785
mm
803
803
kg
128
129
CAB 3267
CAB 3267
mm
2xØ300
2xØ300
m³/h
2540
2540
W
68
68
(3)
A
1,5
1,5
W
2800
2800
mm
1158
1158
mm
560
560
mm
445
445
kg
48
48
(1) Nominal capacities with R404A :
Cold room temperature -25°C.
Ambient air temperature +32°C.
(2) Locked Rotor current of compressor.
(3) Max. operating current.
(4) The sound presure levels (in dB(A) at 10 meters) are mentioned in free field.
Running the equipment in conditions differing from these nominal values may
lead to different results.
The results obtained on the installation site may differ from those in this leaflet,
due to sound reflections from walls, etc.
The reduction of sound level as a function of distance is theoretical and sound
reflection and resonance may alter the results, either on total sound level or on
certain frequencies.
ZF13 Z
ZF15 Z
ZF18 Z
3,10
3,67
4,57
3/8"
3/8"
1/2"
7/8"
7/8"
7/8"
GSS
GSS
GSS
ZF13 Z
ZF15 Z
ZF18 Z
ZF13K4E
ZF15K4E
ZF18K4E
TFD
TFD
TFD
400V/3~/50Hz
51
64
74
8,3
10,0
13,0
1xØ450
1xØ450
2xØ355
4900
4900
5700
400V/3~/50Hz
260
260
220
1,25
1,25
1,00
4
4
7,1
I
I
I
50
51
52
1
1
2
1047
1047
1247
785
785
785
803
803
803
139
140
142
CAB 4167
CAB 3367
CAB 4247
1xØ450
3xØ300
2xØ450
3250
3810
6700
400V/3~/50Hz
250
102
500
0,85
2,25
1,7
2000
3700
3700
960
1558
1560
625
560
625
640
445
640
59
70
95
(1) Nominalbedingungen bei R404A:
Raumtemperatur -25 °C.
Außentemperatur +32 °C.
(2) Stromstärke bei Anlauf (bei blockiertem Rotor) des Verdichters.
(3) Max. Betriebsstrom.
(4) Die Schalldruckpegel (in dBa in 10 m Entfernung) sind Freifeldangaben.
Bei von diesen Nominalbedingungen abweichendem Betrieb kann es zu
anderen Ergebnissen kommen.
Die am Installationsort erzielten Ergebnisse können aufgrund von Reflexionen
(an Wänden usw.) von den Katalogwerten abweichen.
Die Abschwächung des Schalldruckpegels mit zunehmender Entfernung ist
theoretisch, und Schallreflexionen und Resonanzerscheinungen können das
Ergebnis verändern, sowohl im Ganzen wie auch bei bestimmten.
TIEFKÜHLUNG
ZF25 Z
ZF34 Z
ZF41 Z
5,29
7,85
10,01
5/8"
5/8"
7/8"
1"1/8
1"3/8
1"3/8
GSS
GSS
GSS
ZF25 Z
ZF34 Z
ZF41 Z
ZF25K5E
ZF34K5E
ZF41K5E
TFD
TFD
TFD
102
100
118
13,7
25,0
29,0
2xØ355
2xØ450
2xØ500
5700
9750
14300
220
520
900
1,00
1,50
3,6
7,1
14
18
I
II
II
54
56
59
2
3
4
1247
1397
1482
785
820
1105
803
803
852
142
211
249
CAB 4247
CAB 5247
CAB 5267
2xØ450
2xØ500
2xØ500
6700
12700
12200
500
900
900
1,7
2,8
2,8
3700
10050
10500
1560
1870
1870
625
1115
1115
640
992
992
95
215
248
ZF49 Z
11,44
7/8"
1"5/8
GSS
ZF49 Z
ZF49K5E
TFD
139
30,0
2xØ500
14300
900
3,6
18
II
59
4
1482
1105
852
252
CAB 5267
2xØ500
12200
900
2,8
10500
1870
1115
992
248