W
HEN YOU THINK THAT TROUBLE HAS OCCURRED
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An amplifi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
S
PECIFICATIONS
EN
Indoor
Model
Outdoor
Function
Power supply
Capacity
Input
Indoor
Weight
Outdoor
Refrigerant fi lling capacity (R32)
Indoor
IP code
Outdoor
LP ps
Permissible excessive
operating pressure
HP ps
Indoor (Super High/
High/Med./Low)
Noise level (SPL)
Outdoor
Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
EN-6
MSZ-HR25VF
MUZ-HR25VF
Cooling
kW
2.5
kW
0.80
kg
kg
23
kg
0.40
MPa
MPa
dB(A)
43/37/30/21 43/37/30/21 46/38/31/22 44/37/30/21 44/39/34/24 46/40/32/24 45/40/36/28 47/41/34/27
dB(A)
50
Indoor
Outdoor
32°C DB
46°C DB
23°C WB
21°C DB
-10°C DB
15°C WB
27°C DB
24°C DB
18°C WB
20°C DB
-10°C DB
-11°C WB
MSZ-HR35VF
MUZ-HR35VF
Heating
Cooling
Heating
~ /N, 230 V, 50 Hz
3.15
3.4
3.6
0.85
1.21
0.975
8.5
24
0.45
IP 20
IP 24
2.77
4.17
50
51
51
Note:
Rating condition
Cooling — Indoor:
Heating — Indoor:
DB: Dry Bulb
WB: Wet Bulb
MSZ-HR42VF
MSZ-HR50VF
MUZ-HR42VF
MUZ-HR50VF
Cooling
Heating
Cooling
4.2
4.7
5.0
1.34
1.30
2.05
9
34
0.70
0.80
50
51
50
27°C DB, 19°C WB
Outdoor: 35°C DB
20°C DB
Outdoor: 7°C DB, 6°C WB
Heating
5.4
1.55
35
51